Push-Out Tests for Shear Connectors in GFRP-Concrete Composite Bridge Deck Slabs
نویسندگان
چکیده
منابع مشابه
Push-out tests on shear studs in high strength concrete
A lot of push-out tests of shear studs embedded in normal strength concrete were conducted. So current design code methods of the shear studs are based on the test results of studs embedded in normal strength concrete. It also appeared that the strength of connector and the concrete strength are the main factors affecting the behavior of shear connections. But push-out test data of studs embedd...
متن کاملInvestigation of structural behaviour of GFRP reinforced concrete deck slabs through NLFEA
This paper presents a numerical study of the structural behaviour of concrete bridge deck slabs under static patch loads and dynamic traffic loads and an investigation of compressive membrane action (CMA) inside slabs. Those deck slabs were reinforced with Glass Fibre Reinforced Polymer (GFRP) bars. Non-linear finite element analysis (NLFEA) models were established using ABAQUS 6.10 software pa...
متن کاملNon - linear finite - element analysis of punching capacities of steel – concrete bridge deck slabs
j1 Yu Zheng MEng, PhD Associate Professor, Department of Civil Engineering, Dongguan University of Technology, Dongguan, PR China j2 Des Robinson PhD, MRAeS Senior Lecturer, School of Planning, Architecture and Civil Engineering, Queen’s University of Belfast, Belfast, UK j3 Su Taylor PhD, MICE Reader in Structural Engineering, School of Planning, Architecture and Civil Engineering, Queen’s Uni...
متن کاملFoam Concrete Precast Elements in Composite Concrete-GFRP Plate Girders
This paper is focused on using foam concrete as structural element in polymer-concrete composite plate girders. Trial mixes of foam concrete and different proportions of foam agent were considered to obtain the suitable mix that can be used as structural element in composite girders system. Details of the experimental investigations on foam concrete precast slabs and polymer-concrete composite ...
متن کاملAnalysis of the Shear Behavior of Stubby Y-Type Perfobond Rib Shear Connectors for a Composite Frame Structure
Shear connectors are used in steel beam-concrete slabs of composite frame and bridge structures to transfer shear force according to design loads. The existing Y-type perfobond rib shear connectors are designed for girder slabs of composite bridges. Therefore, the rib and transverse rebars of the conventional Y-type perfobond rib shear connectors are extremely large for the composite frames of ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Advanced Concrete Technology
سال: 2018
ISSN: 1346-8014,1347-3913
DOI: 10.3151/jact.16.368