Pupillometry examinations of the human eye with the eye diagnostic device PEP-2000 – First results

نویسندگان

چکیده

Abstract Pupillometry forms the diagnostic basis for numerous pathologies of eye. For this reason, fast and accurate diagnostics in field ophthalmology are essential. Two examination techniques, full-field ERG pupillometry were combined a device developed by ICM e.V. to reduce process both examiners patients. In paper, is examined quality measurements. A study with 12 healthy subjects (3 f, 9 m, 36.33 ± 11.94 years) was conducted evaluate device. The results showed that minimal pupil diameter 40 % higher than literature values. main reason differences low light intensity 15 cd/m2. However, maximum within range researched pupillary reaction measurements show values obtained (amplitude, contraction time peak time) latency 690 ms too high. could be moderate detection rate 50-70 %. Nevertheless, plausible comparable analysis eye PEP-2000. Further work will look at improving rates.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prediction of Refractive Outcome of Second Eye with Partial Adjustment of Intraocular Lens Power of the First Eye

Background and Objective: This study aimed at comparing the results of refractive cataract surgery in patients undergoing sequential surgeries in both eyes. Considering the preoperative refraction and final refraction of the first eye, it is possible to correct the refrative result of cataract surgery using the adjustment of the second eye intraocular lens (IOL) power. Materials and Methods: T...

متن کامل

Study of Optical Models Regarding the Human Eye

Introduction: Until now, many models have been presented for optical study of the human eye. In recent years, surgery on the anterior section of the eye (such as cataract and photo-refractive surgery) has increased, so a study on the optics of the eye and evaluation of vision quality has become more important. Material and Methods: In this article, some of these models are considered. They incl...

متن کامل

Numerical Analysis of the Thermal Interaction of Cell Phone Radiation with Human Eye Tissues

Introduction: The present study aimed to present a numerical analysis of the penetration depth,  specific absorption rate (SAR), and temperature rise in various eye tissues with varying distance between radiation source and exposed human eye tissues (i.e., cornea, posterior chamber, anterior chamber, lens, sclera, vitreous humor, and iris) at frequencies of 900 and1800 MHz. Materials and Method...

متن کامل

Red Eye due to Leech in the Eye

A 65–yrs-old man referred for an ocular discomfort and red eye. The clinical diagnosis was leech in the left eye and its species confirmed as being Limnatis nilotica. Ocular leech infestation should be considered in patients with a history of swimming or washing their face in streams and lakes. Attention should also be given to ocular leech infestation in the differential diagnosis of ocular tr...

متن کامل

The need for routine eye examinations.

PURPOSE To determine the incidence and causes of vision loss to assist in the objective determination of the preferred frequency of routine screening for those with normal vision. METHODS A prospective, population-based study of people aged 40 or more years. Standardized examination protocols were used that included presenting and best corrected visual acuity, visual field testing, and compre...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Current Directions in Biomedical Engineering

سال: 2022

ISSN: ['2364-5504']

DOI: https://doi.org/10.1515/cdbme-2022-1165