Punching Shear Stress in Post-Tensioned Transfer Plate of Multi-Story Buildings

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Meniscal shear stress for punching.

AIM Experimental determination of the shear stress for punching meniscal tissue. METHODS Meniscectomy (surgical treatment of a lesion of one of the menisci) is the most frequently performed arthroscopic procedure. The performance of a meniscectomy is not optimal with the currently available instruments. To design new instruments, the punching force of meniscal tissue is an important parameter...

متن کامل

Sound insulation in multi-story timber buildings

During on an extensive investigation of a multi-story timber building with light-frame construction, several stages of the building process and their impact on sound transmission were observed. The sound insulation properties of the building components were measured before and while the buildings were occupied. Furthermore, interviews with the occupants were conducted. This procedure made it po...

متن کامل

Shake Table Tests of Reinforced Concrete Flat Plate Frames and Post-tensioned Flat Plate Frames

A research study was undertaken to assess performance of flat plate systems constructed with slab shear reinforcement under dynamic loads. The research program consisted of shake table tests and accompanying analytical studies of two, approximately one-third scale, two-story, two-bay, slab-column frames. One specimen was constructed with reinforced concrete (RC) slab, whereas the other specimen...

متن کامل

Strength of Footing with Punching Shear Preventers

The punching shear failure often governs the strength of the footing-to-column connection. The punching shear failure is an undesirable failure mode, since it results in a brittle failure of the footing. In this study, a new method to increase the strength and ductility of the footing was proposed by inserting the punching shear preventers (PSPs) into the footing. The validation and effectivene...

متن کامل

Numerical solution of base shear in high tensioned cable antenna

A finite element solution based on equevalent elements is proposed for the static and dynamic analysis of tallhigh tensioned cable antennas. To reduce high number of degrees of freedom in space frame body of a structure, a simple equivalent beam element is defined for each simulative substructure. This numerical procedure is applicable to analyze complex three dimensional assemblies of substruc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Applied Sciences

سال: 2020

ISSN: 2076-3417

DOI: 10.3390/app10176015