Pulsed Laser-Induced Thermal Damage in Whole Blood
نویسندگان
چکیده
منابع مشابه
Investigation of pulsed laser induced dewetting in nanoscopic metal films: Thermal modeling and experiments
Pulsed laser-induced melting and dewetting of nanoscopic metal films have been used to assemble metal nanoparticles having spatial order and monomodal size distribution on SiO 2 /Si substrates. Spatial pattern selection during dewetting determines the final particle size and inter-particle distance. Pattern selection and dynamical progression of interface disturbances are greatly dependent on p...
متن کاملAnalysis of the theory of thermal damage in biological tissues caused by Laser beam
Introduction: In laser surgery, the laser beam can evaporate and cut the tissue like a small surgical knife when the tissue temperature is heated to 100 degrees Celsius. a complete understanding of the distribution of damage in both pathologic tissue and surrounding tissue is necessary. Although the test is the most realistic solution for treating medical problems, for this rea...
متن کاملThermoelastic wave induced by pulsed laser heating
In this work, a generalized solution for the thermoelastic plane wave in a semi-infinite solid induced by pulsed laser heating is developed. The solution takes into account the non-Fourier effect in heat conduction and the coupling effect between temperature and strain rate, which play significant roles in ultrashort pulsed laser heating. Based on this solution, calculations are conducted to st...
متن کاملPulsed laser-induced formation of silica nanogrids
UNLABELLED Silica grids with micron to sub-micron mesh sizes and wire diameters of 50 nm are fabricated on fused silica substrates. They are formed by single-pulse structured excimer laser irradiation of a UV-absorbing silicon suboxide (SiOx) coating through the transparent substrate. A polydimethylsiloxane (PDMS) superstrate (cover layer) coated on top of the SiOx film prior to laser exposure ...
متن کاملBlood-Induced Joint Damage
Objective. Four days of blood exposure leads to irreversible cartilage damage in vitro. In contrast, intermittent intra-articular blood injections twice a week during 4 weeks (mimicking micro-bleeds) in a canine model resulted in transient damage only. In this study, it was evaluated whether acute joint bleeds are more harmful than micro-bleeds in a canine model of knee arthropathy. Design. Sev...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Biomechanical Engineering
سال: 1999
ISSN: 0148-0731,1528-8951
DOI: 10.1115/1.429642