Pulsed galvanostatic control of a solid-contact ion-selective electrode for potentiometric biosensing of microcystin-LR

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Potentiometric Determination of Dopamine Using a Solid-Contact Polymer Membrane Ion-Selective Electrode

Potentiometric Determination of Dopamine Using a Solid-Contact Polymer Membrane Ion-Selective Electrode Tanji Yin1 2 3 ∗ and Wei Qin1 1Key Laboratory of Coastal Zone Environmental Processes, Yantai Institute of Coastal Zone Research YIC , Chinese Academy of Sciences CAS ; Shandong Provincial Key Laboratory of Coastal Zone Environmental Processes, YICCAS, Yantai, Shandong 264003, P. R. China 2So...

متن کامل

Novel Solid-Contact Ion-Selective Microelectrodes for Localized Potentiometric Measurements

The design and properties of novel type of solid-contact ionophore-based ion-selective microelectrodes are reported. The microelectrode is based on an insulated needle-shaped metallic wire with an exposed apex. The ion-to-electron transducer is made of poly(3-octylthiophene-2,5-diyl) and placed between an ion-selective membrane and the metallic tip. The ion-selective polyvinyl chloride-based me...

متن کامل

Solid-Contact Reference Electrode for Ion-Selective Sensors

This work presents a flexible miniaturized ion-selective sensor consisting of a solidcontact reference electrode (RE) and ion-selective electrodes (ISE) fabricated on the same foil. The flexible ion sensor was based on AgCl electrodes screen printed on polyethylene terephthalate foil. The RE was formed by casting a mixture of plasticized polyvinylchloride (PVC) and KCl on the AgCl electrode. Th...

متن کامل

A Novel Carbon Paste Electrode for Potentiometric Determination of Vanadyl Ion

Carbon paste electrode was modified by disodium 2,4-diamino-7-methylbenzo[g] pteridine-5,10-dioxide to fabricate a sensor for potentiometric determination of vanadyl ion (VO2+) in aqueous medium. The new ligand was synthesized in three steps with high yield. The optimal composition of the carbon paste was made of graphite powder (64.5%), ionophore (16.6%), paraffin oil (17.8%), a...

متن کامل

A Solid-Contact Ion Selective Electrode for Copper(II) Using a Succinimide Derivative as Ionophore

All-solid-state sensors with polyvinyl chloride (PVC)-based membranes using off-the-shelf N-hydroxysuccinimide (NHS) and succinimide (Succ) ionophores were prepared using DOP (dioctyl phthalate) and NPOE (ortho-nitrophenyloctyl ether) as plasticizers. Good responses were obtained when NHS was used. The potentiometric response of the proposed electrode is independent of pH over the range 2-6. Th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Sensors and Actuators B: Chemical

سال: 2016

ISSN: 0925-4005

DOI: 10.1016/j.snb.2016.02.121