Pulse-shape discrimination between electron and nuclear recoils in a NaI(Tl) crystal
نویسندگان
چکیده
منابع مشابه
Discrimination between Nuclear Recoils and Electron Recoils by Simultaneous Detection of Phonons and Scintillation Light
We have developed a detector, consisting of a cryogenic calorimeter with a scintillating crystal as absorber, and a second calorimeter for the detection of the scintillation light, both operated at 12 mK. Using a CaWO4 crystal with a mass of 6 g as scintillating absorber, we have achieved a discrimination of nuclear recoils against electron recoils with a suppression factor of 99.7% at energies...
متن کاملElectron-nuclear recoil discrimination by pulse shape analysis
In the framework of the " ULTIMA " project, we use ultra cold superfluid 3 He bolometers for the direct detection of single particle events, aimed for a future use as a dark matter detector. One parameter of the pulse shape observed after such an event is the thermalization time constant τ b. Until now it was believed that this parameter only depends on geometrical factors and superfluid 3 He p...
متن کاملPulse-shape discrimination with PbWO4 crystal scintillators
The light output, α/β ratio, and pulse shape have been investigated at −25◦ C with PbWO4 crystal scintillators undoped, and doped by F, Eu, Mo, Gd and S. The fast 0.01 − 0.06 μs and middle 0.1 − 0.5 μs components of scintillation decay were observed for all the samples. Slow components of scintillation signal with the decay times 1− 3 μs and 13− 28 μs with the total intensity up to ≈ 50% have b...
متن کاملMeasurements of Scintillation Efficiency and Pulse-Shape for Low Energy Recoils in Liquid Xenon
Results of observations of low energy nuclear and electron recoil events in liquid xenon scintillator detectors are given. The relative scintillation efficiency for nuclear recoils is 0.22 ± 0.01 in the recoil energy range 40 keV 70 keV. Under the assumption of a single dominant decay component to the scintillation pulse-shape the log-normal mean parameter T0 of the maximum likelihood estimator...
متن کاملcohesion and cohesive devices in a contrastive analysis between ge and esp texts
the present study was an attempt to conduct a contrastive analysis between general english (ge) and english for specific purposes (esp) texts in terms of cohesion and cohesive devices. to this end, thirty texts from different esp and ge textbooks were randomly selected. then they were analyzed manually to find the frequency of cohesive devices. cohesive devices include reference, substitution, ...
15 صفحه اولذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of High Energy Physics
سال: 2015
ISSN: 1029-8479