overvoltage caused by winding terminal arrangement of three phase transformer

usually both ends of a transformer winding are at the same side of the magnetic core. with this arrangement there are automaticaly the same number of the turns for each winding in both core windows next to the middle leg of a three phase three leg core type transformer. contrary to this arrangement it is possible to put the two ends of a winding at the different sides of the core. in this case ...

متن کامل

Recognition and Location of Power Transformer Turn to Turn Fault by Analysis of Winding Imposed Forces

Turn to turn fault is one of the major internal failures in the power transformers that if it is not quickly detected, can be extended and led to a complete transformer breakdown. So, the diagnosis and location of the turn to turn fault of the power transformer, as one of the most important equipment in the power system, is the main objective of this paper. For this purpose, a detailed model of...

متن کامل

Comparison of Impulse Wave and Sweep Frequency Response Analysis Methods for Diagnosis of Transformer Winding Faults

Monitoring of winding faults is the most important item used to determine the maintenance status of a transformer. Commonly used methods for winding-fault diagnosis require the transformer to exit operation before testing and an external exciting signal, whether the transformer is malfunctioning or not. However, if an overvoltage signal can be regarded as a broadband excitation source for fault...

متن کامل

Transfer Function of Transformer Winding for Frequency Response Analysis Based on Traveling Wave Theory

This paper presents an improved model of uniform transformer winding for frequency response analysis (FRA), based on traveling wave theory. The accurate representation of the losses and detailed consideration of measurement chains are the main features of the model. The transfer function expression of the transformer winding and equivalent distributed-parameter circuit for FRA have been derived...

متن کامل

Characterization of Power Transformer Electromagnetic Forces Affected by Winding Faults

Electromagnetic forces in power transformer windings are produced by interaction between the leakage fluxes and current passing them. Since the leakage flux distribution along the windings height is in two axial and radial directions, so the electromagnetic forces have two components, radial and axial. There is a risk that a large electromagnetic force due to the short circuit or inrush current...

متن کامل