Pulp Vitality Testing with a Developed Universal Pulse Oximeter Probe Holder
نویسندگان
چکیده
منابع مشابه
Evaluation of efficacy of a pulse oximeter to assess pulp vitality.
BACKGROUND To evaluate the efficacy of pulse oximeter as a pulp vitality tester. MATERIALS AND METHODS The sample group consisted of 60 patients of age 15 to 30 years with normal maxillary anterior teeth. Thirty nonvital teeth with complete endodontic fillings were tested as control group. Systemic oxygen saturation values from the patient's fingers served as the control sample for comparison...
متن کاملDevelopment and initial testing of a pulse oximetry prototype for measuring dental pulp vitality
The guiding principle of endodontic treatment is to preserve teeth while maintaining its aesthetic and functional roles. To accomplish this goal the assessment of teeth pulp vitality is very important since it will determine the procedures that should be adopted and define the therapy strategy. Currently, the most commonly tests for determining dental pulp state are the thermal and the electric...
متن کاملHigh altitude testing of pulse oximeter.
I Boushey HA, Holtzman MJ. Experimental airway inflammation and hyperreactivity: searching for cells and mediators. Am Rev Respir Dis 1985;131: 312-3. 2 Bennett JD, Davies RJ. A comparison of histamine and methacholine bronchial challenges using the DeVilbiss 646 nebuliser and the Rosenthal-French dosimeter. BrJ' Dis Chest 1987;81:252-9. 3 Woolcock AJ, Peat JK, Salome CM, et al. Prevalence of b...
متن کاملComparative Study of Pulp Vitality in Primary and Young Permanent Molars in Human Children with Pulse Oximeter and Electric Pulp Tester
AIM AND OBJECTIVE The purpose of this study was to compare the pulp testing methods (pulse oximetry and electric pulp test) in primary and young permanent teeth of children. MATERIALS AND METHODS The study included a total of 155 children aged 4 to 15 years. Twenty children formed control group I. Study group included all healthy, 85 primary 2nd molars in group II and 85 permanent 1st molars ...
متن کاملA Pulse Oximeter
The objective of this work was to develop a prototype for a pulse oximeter. Given the necessity, in most medical interventions, to monitorize Oxygen saturation in peripheral blood (SpO2) a pulse oximeter is highly necessary in any operating room or intensive care unit. The electronic device was built recurring mostly to Integrated Circuit (IC) and its control was performed via a programmed micr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Medicina
سال: 2021
ISSN: 1648-9144
DOI: 10.3390/medicina57020101