Pulmonary venous baffle obstruction following senning procedure - Role of transesophageal echocardiography

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Late development of pulmonary venous obstruction following Mustard's operation using a dacron baffle.

Three patients developed late pulmonary vein obstruction (PVO) following Mustard's operation for transposition of the great arteries. In all three the absence of PVO had been documented by an earlier postoperative cardiac catheterization. At reoperation shrinkage and kinking of the dacron baffle was evident. After Mustard's operation, patients should be observed closely for symptoms and signs o...

متن کامل

[Transesophageal echocardiography in Ross procedure].

BACKGROUND AND OBJECTIVES Ross procedure is one of the surgical procedures for correction of severe congenital aortic insufficiency. Intraoperative transesophageal echocardiography is essential for optimal surgical evaluation. Furthermore, it is able to assess the blood volume profile and the need for administration of vasoactive drugs during surgery. CASE REPORT This is a 15-year old teenage...

متن کامل

The role of transesophageal echocardiography during the Ross procedure.

Pulmonary autograft replacement of the aortic valve, the “Ross procedure,” involves transplantation of the native pulmonary valve into the aortic position and reconstruction of the right ventricular outflow tract with a cryopreserved pulmonary or aortic homograft. In any surgeon’s hands this operation is technically challenging and successful performance of the Ross procedure requires strategie...

متن کامل

Pulsed Doppler echocardiographic assessment of the pulmonary venous pathway after the Mustard or Senning procedure for transposition of the great arteries.

Pulsed Doppler evaluation of pulmonary venous flow was performed in three groups of patients who had undergone either a Mustard or Senning procedure. Group I consisted of 43 patients in sinus rhythm who had undergone the Mustard procedure 9 months or more before the Doppler examination and 16 who were evaluated immediately after surgery. Group II consisted of 12 patients in sinus rhythm who had...

متن کامل

Inadequate Venous Drainage-transesophageal Echocardiography as Rescue

Malposition of venous cannula can cause inadequate venous drainage during cardiopulmonary bypass. It would be good clinical practice to use TEE to check the position of inferior venous cannula to avoid this problem at the earliest.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Annals of Cardiac Anaesthesia

سال: 2020

ISSN: 0971-9784

DOI: 10.4103/aca.aca_195_18