PULLOUT CHARACTERISTICS OF DIAMETER-EXPANDED ANCHOR IN SAND
نویسندگان
چکیده
منابع مشابه
Pullout Capacity of Model Piles in Sand
A large scale experimental program using vertical and batter model piles in sand subjected to pull out loads has been carried out in a model tank of size 1m x 1m x 1m. Mild steel pipes of varying diameters, lengths, and shapes are used as model piles. A poorly graded river sand having specific gravity G= 2.67, Uniformity coefficient= 3.53, emax = 0.81, emin = 0.54 has been used as foundation me...
متن کاملPullout Load Analysis of Reinforced Concrete Anchor Shafts
In this paper, results obtained in both conventional and finite element analysis of straight and belled anchor shafts subjected to a pullout force are presented. In numerical analysis, it is assumed that no drainage takes place during the anchor pullout. Comparisons between two conventional methods of analysis for ultimate pullout load and the results obtained by the finite element analysis are...
متن کاملPullout capacity of batter pile in sand
Many offshore structures are subjected to overturning moments due to wind load, wave pressure, and ship impacts. Also most of retaining walls are subjected to horizontal forces and bending moments, these forces are due to earth pressure. For foundations in such structures, usually a combination of vertical and batter piles is used. Little information is available in the literature about estimat...
متن کاملHeaded Anchor/Engineered Cementitious Composites (ECC) Pullout Behavior
In this paper, the inelastic damage process in Engineered Cementitious Composites (ECC) in the high stress concentration zone adjacent to the head of an embedded anchor under tensile load was examined experimentally and numerically. An FEM model together with a tensile strain-hardening material model of ECC was developed to simulate the damage process leading to final failure. Experimental obse...
متن کاملA novel, resorbable suture anchor: pullout strength from the human cadaver greater tuberosity.
The pullout strength of a collagen bone anchor that creates interference fixation as the result of radial swelling on hydration was compared with a Mitek rotator cuff anchor after insertion into the greater tuberosity of human cadaver humeri. Bones were fully hydrated at 37 degrees C. Stiffness, peak load, and the mode of failure were recorded. Real and apparent bone densities were measured. Pe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Doboku Gakkai Ronbunshuu C
سال: 2010
ISSN: 1880-604X
DOI: 10.2208/jscejc.66.845