Pull Back Balloon Assisted Wiring Technique for Treatment of Extremely Angulated Bifurcation Lesion
نویسندگان
چکیده
منابع مشابه
Comparison Between Balloon-Assisted and Stent-Assisted Technique for Treatment of Unruptured Internal Carotid Artery Aneurysms
PURPOSE To compare clinical and angiographic outcomes between balloon-assisted (BAC) and stent-assisted coiling for internal carotid artery unruptured aneurysms (ICA-UA). MATERIALS AND METHODS A total of 227 ICA-UA in 190 patients were treated with BAC (120 patients, 141 ICA-UA) or SAC (70 patients, 86 ICA-UA. We compared characteristics of patients and ICA-UA, and clinical and angiographic o...
متن کاملDouble lumen remodelling balloon: a new technique for treatment of bifurcation aneurysms.
Bifurcation aneurysms (carotid bifurcation aneurysms, top of basilar artery aneurysms and middle cerebral artery aneurysms) are frequently treated by endovascular treatment (EVT) but their treatment is sometimes difficult singularly when the neck is wide. The "remodelling technique" is used for the treatment of these difficult aneurysms. However, the use of this technique is more complicated in...
متن کاملPower-assisted liposuction and the pull-through technique for the treatment of gynecomastia.
BACKGROUND Gynecomastia is a common condition affecting many adolescent and adult males. Surgical techniques utilizing a variety of incisions, excisions, suction-assisted lipectomy, ultrasound-assisted liposuction, power-assisted liposuction, or some combination of these methods have been used in the treatment of gynecomastia. This article describes the authors' method of using power-assisted l...
متن کاملHyperForm balloon-assisted endovascular neck bypass technique to perform balloon or stent-assisted treatment of cerebral aneurysms.
We describe a technique to bypass aneurysm neck using the HyperForm balloon to perform balloon- or stent-assisted endovascular treatment of complex large or giant aneurysms with very wide neck in which other methods would fail to obtain an access distal to the aneurysm.
متن کاملBalloon-assisted enteroscopy using a single-balloon technique.
teroscopy system (Olympus Medical Systems Europa GmbH, Hamburg, Ger− many; l" Fig. 1) consists of a high−resolu− tion endoscope (XSIF−Q160Y) with a working length of 200 cm, and an outer diameter of 9.2 mm, and a flexible over− tube (XST−BY3A; l" Fig. 2) with a working length of 132 cm and an outer diameter of 13.2 mm. A latex−free balloon is only attached at the tip of the single−use sili− con...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Cardiology Research and Cardiovascular Medicine
سال: 2019
ISSN: 2575-7083
DOI: 10.29011/2575-7083.000048