Proton-Proton Scattering at 105 Mev and 75 Mev
نویسندگان
چکیده
منابع مشابه
Proton-Deuteron Elastic Scattering from 2.5 to 22.5 MeV
We present the results of a calculation of differential cross sections and polarization observables for proton-deuteron elastic scattering, for proton laboratory energies from 2.5 to 22.5 MeV. The Paris potential parametrisation of the nuclear force is used. As solution method for the charged-composite particle equations the ’screening and renormalisation approach’ is adopted which allows to co...
متن کاملPROTON RADIOGRAPHY EXPERIMENT BASED ON A 100 MeV PROTON CYCLOTRON*
A proof-of-principle test-stand for proton radiography is under construction at China Institute of Atomic Energy (CIAE). This test-stand will utilize the 100 MeV proton beam provided by the compact cyclotron CYCIAE-100, which has been built in the year of 2014, to radiograph thin static objects. The assembling of the test-stand components is finished by now. We will carry out the first proton r...
متن کاملSLAC -PUB-238 December 1966 THE ABSOLUTE VALUE OF Axx (90’) FOR PROTON-PROTON SCATTERING AT 11.4 MeV
Because of the deterioration of the target under proton bombardment, Catillon, Chapellier, and Garreta normalize their measurements of Axx(900) and Ayy(900) at 11,4, 19.15, 23.45, and 26.5 MeV to the value of Axx(900) at 11.4 MeV. In order to provide an absolute normalization for these experiments we note that at 90° the value of A, is related to the ratio A Y-d Axx by the equation l+Axx = (l-A...
متن کاملConsider potential of gold nanoparticles with proton therapy compared with KV and MEV X-ray therapy.
Introduction: Many study shown the effectiveness dose enhancement with gold nanoparticles (GNPs), especially with low-energy x-rays. Recently, proton beam radiation therapy (PBRT) has attention as a treatment for tumors. The advantage in PBRT, which releases high dose at the controllable Bragg peak position that localized for Au target and the released dose increased in depth....
متن کاملDesign of 100 Mev Proton Beam Irradiation Facility for the Pefp 100 Mev Linac *
The Proton Engineering Frontier Project (PEFP) will install a 100-MeV proton linear accelerator at Gyeong-ju site. For the beam commissioning of 100 MeV proton linac, the two target rooms (TR 103, TR 23) will be prepared as a starter among 10 target room. To design the irradiation equipment in TR 103, we have investigated general propagation shape and spatial distribution of proton beam, when 1...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Physical Review
سال: 1951
ISSN: 0031-899X
DOI: 10.1103/physrev.83.274