Protection of Atrial Electrode Wire in Extracting VDD Lead
نویسندگان
چکیده
منابع مشابه
Influence Of Inter Electrode Atrial Lead Distance On Acapconfirm™ Viability.
Introduction: The AcapConfirm™ feature available with the Zephyr pacemaker family (St. Jude Medical) is designed for monitoring patient's atrial capture threshold periodically, and automatically adjusting the atrial pulse amplitude. Previous studies showed a relative low proportion of patients at three months follow-up with recommended automatic atrial capture after the AcapConfirm™ viability t...
متن کاملImplantable atrial defibrillator with a single-pass dual-electrode lead.
OBJECTIVES We examined the feasibility and efficacy of using a single-pass, dual-electrode (Solo) lead for atrial fibrillation (AF) detection and defibrillation. BACKGROUND The efficacy and safety of an implantable atrial defibrillator (IAD) has been extensively studied; however, separate right atrial (RA) and coronary sinus (CS) defibrillation leads are used for the present system. METHODS...
متن کامل[Safety and effectiveness of single-lead VDD pacing].
INTRODUCTION AND OBJECTIVES Single-lead VDD pacing provides the physiological benefits of atrioventricular synchrony with the convenience of a single-lead system. However, concern remains about the method's safety and effectiveness. METHOD In total, 700 patients with single-lead VDD pacemakers were evaluated retrospectively. The following parameters were recorded: age, sex, etiology, the symp...
متن کاملLong-term follow-up of single-lead VDD pacing.
Long-term outcomes of single-lead VDD pacing were studied retrospectively and partly prospectively. Records were analysed of 81 patients out of 133 in whom a single-lead VDD pacemaker was implanted between January 1993 and December 1997 and who attended a follow-up clinic more than two years after the implant. Forty-eight of them attended a prospective follow-up 54 +/- 15 months after the impla...
متن کاملIntermittent atrial undersensing in single-lead VDD pacemakers in patients with bradycardia-sensitive repolarization: a possible mechanism for ventricular arrhythmia.
Intermittent atrial undersensing in patients with single-lead VDD pacemakers is regarded as being of limited clinical significance. Nevertheless, in patients with bradycardia-mediated repolarization abnormalities, undersensing could result in RR-interval oscillations due to changes in pacemaker mode and this could act as a trigger for the initiation of torsades de pointes. We report our finding...