Protection Method Based on Wavelet Entropy for MMC-HVDC Overhead Transmission Lines

نویسندگان

چکیده

Recent technological developments in modular multilevel converter-based high-voltage direct current (MMC-HVDC) transmission systems have shown significant advantages over the traditional HVDC and two-level voltage source converter (VSC) systems. However, there are a lack of studies on protection methods for MMC-HVDC overhead lines where method should be able to provide fast accurate response identify lightning strikes. In this paper, wavelet entropy-based is proposed. Due capability revealing time–frequency distribution features, proposed combines entropy characteristics different faults. Simulation results show that can accurately quickly determine types faults or disturbances with appropriate noise tolerance. addition, impact ground resistor fault distance performance studied.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pole-to-Ground Fault Analysis and Fast Protection Scheme for HVDC Based on Overhead Transmission Lines

Flexible direct current (DC) transmission network technology is an effective method for large capacity clean energy access to power grids, but the DC short-circuit fault detection for it is a difficult problem. In this paper, the pole-to-ground fault transient characteristics in a multi-terminal DC power grid, based on overhead transmission lines and DC circuit breakers, are analyzed firstly. T...

متن کامل

A Pilot Directional Protection for HVDC Transmission Line Based on Relative Entropy of Wavelet Energy

On the basis of analyzing high-voltage direct current (HVDC) transmission system and its fault superimposed circuit, the direction of the fault components of the voltage and the current measured at one end of transmission line is certified to be different for internal faults and external faults. As an estimate of the differences between two signals, relative entropy is an effective parameter fo...

متن کامل

Research of Bipolar HVDC Transmission Lines based on Traveling Wave Differential Protection

The principle of the traveling wave based differential protection for bipolar HVDC transmission lines is proposed in the paper. Unlike the traditional current differential protection, the quantity of current is replaced by the quantity of the traveling wave for comparison. The traveling wave at the remote end is transferred to the local end for comparison to the local traveling wave. For the bi...

متن کامل

Accurate Electromagnetic Transient Simulations of HVDC Cables and Overhead Transmission Lines

This paper introduces three different procedures for improvements in the accuracy at very low frequencies of time domain simulation models for overhead lines and underground cables. In the first two methods, a suitable modification is introduced to the functional form of the rational function approximated in the curve fitting procedure for the phasedomain model, such that the model is perfectly...