Prosthetic Surgical Templates and Dental Implant Site Time Preparation: An In Vitro Study

نویسندگان

چکیده

Numerous types of prosthodontics surgical guides, with and without metallic sleeves, have been found to be useful in clinical studies. The aim this vitro research was compare the time required complete procedure two differently designed prosthetic templates. Ten identical prototype models mandible based on a CBCT optical scan partially edentulous patient missing teeth numbers 37, 46, 47 were prepared then printed. Five these used for implant site preparation guide metal sleeves dedicated kit, other five same performed kit. measured recorded. Statistical analysis using Student’s t-test independent samples. Differences between groups statistically significant (t = −9.94; df 28; p 0.0000) lower value favor templates sleeves. Different or seemed an important factor which can significantly impact and, therefore, overall procedure.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Influence of Site Preparation (Countersinking) on Initial Dental Implant Stability. An in vitro Study Using Resonance Frequency Analysis

Primary implant stability is considered to be a critical factor for obtaining successful osseointegration [1]. Studies using Resonance Frequency Analysis (RFA) have demonstrated that initial implant stability is determined by the density of the bone, the surgical technique used, and the design of the implant [2, 3]. While different implant designs have shown similar results of higher stabilitie...

متن کامل

The effects of surgical preparation techniques and implant macro-geometry on primary stability: An in vitro study

BACKGROUND The attainment of a good primary stability is a necessary condition to ensure the success of osseointegration in implantology. In type IV cancellous bone, however, it is possible that a reduced primary stability can lead to an increased rate of failure. The aim of this study was therefore to determine, with the help of the resonance frequency (Osstell mentor), which technique of impl...

متن کامل

Application of CAD/CAM dental implant surgical templates in immediate implant surgery in esthetic area : A case report

CAD/CAM (Computer-aided design/Computer-aided manufacturing) dental implant surgical templates applied in the immediate implant surgery in esthetic area,is beneficial to acquire appropriate three-dimensional position,realize the transformation that from virtual plan to practical surgery, from traditional surgery depended on experience to digital and accurate surgery, improve predictability, acc...

متن کامل

Heat production during prosthetic preparation of a one-piece dental implant.

PURPOSE Preparation of a one-piece dental implant abutment is often needed to achieve a proper emergence profile for a definitive restoration. However, this procedure may compromise osseointegration through the production of heat. The aim of this study was to measure heat production during implant abutment preparation with different volumes of water irrigation using a one-piece implant system. ...

متن کامل

An alternative method to record rising temperatures during dental implant site preparation: a preliminary study using bovine bone.

Overheating is constantly mentioned as a risk factor for bone necrosis that could compromise the dental implant primary stability. Uncontrolled thermal injury can result in a fibrous tissue, interpositioned at the implant-bone interface, compromising the long-term prognosis. The methods used to record temperature rise include either direct recording by thermocouple instruments or indirect estim...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Prosthesis

سال: 2022

ISSN: ['2673-1592']

DOI: https://doi.org/10.3390/prosthesis4010004