Prospective Evaluation of Extraocular Motility Following Double-Plate Molteno Implantation
نویسندگان
چکیده
منابع مشابه
success rate and complications of single-plate molteno tube implantation in patients with glaucoma
purpose: to evaluate the success rate and complications of single-plate molteno tube implantation in patients with intractable glaucoma. methods: this study was conducted on records of patients who underwent molteno tube implantation from 1995 to 2000 and had at least 18 months of follow-up. results: thirty six eyes of 35 patients including 20 male and 15 female subjects with mean age of 29.7±2...
متن کاملHypertensive Phase Following Silicon Plate Ahmed Glaucoma Valve Implantation.
PURPOSE To estimate the incidence of hypertensive phase (HP) following silicone plate Ahmed glaucoma valve implantation and to explore the risk factors for developing HP. METHODS A total of 325 eyes from 325 patients who underwent Ahmed glaucoma valve implantation for uncontrolled intraocular pressure (IOP) and were followed for at least 1 year were included. The HP was defined as IOP>21 mm H...
متن کاملOtago glaucoma surgery outcome study: comparative results for the 175-mm2 Molteno3 and double-plate molteno implants.
OBJECTIVE To evaluate the efficacy of the 175-mm2 Molteno3 implant in patients with nonneovascular glaucoma. METHODS A hospital-based, retrospective historical control comparative case series comparing results in the first 87 eyes to receive the 175-mm(2) Molteno3 implant with those in a control group of 115 eyes receiving the 274-mm(2) double-plate Molteno implant. RESULTS Success was defi...
متن کاملRadiographic Evaluation of Marginal Bone Loss Following Immediate and Delayed Implantation
Background and Aim: Intraosseous implants can be placed using three different techniques: immediate, early, and delayed. The aim of this study was to compare the changes in the marginal bone level around implants after immediate and delayed im-plant placement. Materials and Methods: In the present prospective cohort study, 26 implants were placed in 26 patients divided into two groups. In grou...
متن کاملAhmed glaucoma valve and single-plate Molteno implants in treatment of refractory glaucoma: a comparative study.
PURPOSE To report 2-year follow-up data after Ahmed valve implantation (New World Medical, Inc) and Molteno single-plate implantation surgical treatment of refractory glaucoma. DESIGN Prospective, randomized, comparative study. METHODS Patients with refractory glaucoma, defined as uncontrolled intraocular pressure (IOP) of more than 21 mm Hg despite maximal antiglaucoma medication, previous...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Archives of Ophthalmology
سال: 1999
ISSN: 0003-9950
DOI: 10.1001/archopht.117.9.1155