Proposal of Hybrid Discontinuous PWM Technique for Five-Phase Inverters under Open-Phase Fault Operation

نویسندگان

چکیده

One of the most common issues in inverters are open-circuit faults (OPF). In this scenario, a proper fault-tolerant technique must be used to improve motor performance. Although basic modulation techniques normally preferred, paper proposes discontinuous pulse-width algorithm (HD-PWM) operate five-phase under single OPF. particular, loss equalization between remaining switches after fault occurs is main objective HD-PWM algorithm, thus preventing future from occurring. The efficiency and harmonic distortion proposed compared well-known sinusoidal PWM by simulation experimentation OPF conditions. results obtained show great performance technique, obtaining relevant improvement.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fault Diagnosis and Fault-Tolerant SVPWM Technique of Six-phase Converter under Open-Switch Fault

In this paper, a new open-switch fault diagnosis method is proposed for the six-phase AC-DC converter based on the difference between the phase current and the corresponding reference using an adaptive threshold. The open-switch faults are detected without any additional equipment and complicated calculations, since the proposed fault detection method is integrated with the controller required ...

متن کامل

Adaptive Harmonic Elimination Technique in Single Phase PWM Inverters

PWM inverters ideally shift the output voltage spectrum around the switching frequency. Thus ideally PWM inverters do not introduce any significant lower order harmonics. However, in real systems, due to deadtime effect, device drops and other non-idealities lower order harmonics are present. In order to attenuate these lower order harmonics and hence to improve the quality of output current, t...

متن کامل

Investigating Direct Torque Control of Six-Phase Induction Machines Under Open Phase Fault Conditions

This paper presents analysis and evaluation of classical direct torque control(DTC), for controlling a symmetrical six phase induction motor (SPIM) under open phasefault conditions. The machine has two three-phase windings spatially shifted by 60 electricaldegrees. The strategy of the proposed method consists of choosing the switching modesaccording to the configuration of living phases in such...

متن کامل

Fault-Tolerant Control of Five-Phase Induction Motor Under Single-Phase Open

This paper deals with fault-tolerant control of five-phase induction motor (IM) drives under single-phase open. By exploiting a decoupled model for five-phase IM under fault, the indirect field-oriented control ensures that electromagnetic torque oscillations are reduced by particular magnitude ratio currents. The control techniques are developed by the third harmonic current injection, in orde...

متن کامل

Compensation of Discontinuous Conduction in Three Phase Voltage Source PWM Inverters

Nowadays the increasing utilization of alternative energy sources demand power converters capable of delivering high quality energy to the low voltage grid. Good dead time compensation and linear operation are essential to keep low order harmonics at acceptable levels. High-current operating conditions are well handled by traditional methods, but low current behaviour and waveforms with multipl...