Proposal of a New Double-Nozzle Technique for In-Gas-Jet Laser Resonance Ionization Spectroscopy
نویسندگان
چکیده
This paper proposes a new double-nozzle technique for in-gas-jet laser resonance ionization spectroscopy. We explored the functionality of this through detailed gas dynamic and Monte Carlo atom-trajectory simulations, in which results are presented discussed. The similar computer simulations JetRIS setup (as typical representative conventional nowadays) also direct comparison calculation proposed with one shows that has many advantages compared used at GSI future high-resolution spectroscopic study heaviest elements. To fully implement all existing (or under construction) setups spectroscopy, it will be enough to replace supersonic nozzle miniature device described paper.
منابع مشابه
Towards high-resolution laser ionization spectroscopy of the heaviest elements in supersonic gas jet expansion
Resonant laser ionization and spectroscopy are widely used techniques at radioactive ion beam facilities to produce pure beams of exotic nuclei and measure the shape, size, spin and electromagnetic multipole moments of these nuclei. However, in such measurements it is difficult to combine a high efficiency with a high spectral resolution. Here we demonstrate the on-line application of atomic la...
متن کاملJet-associated resonance spectroscopy
We present a model-independent study aimed at characterising the nature of possible resonances in the jetphoton or jet-Z final state at hadron colliders. Such resonances are expected in many models of compositeness and would be a clear indication of new physics. At leading order, in the narrow width approximation, the matrix elements are parameterised by just a few constants describing the coup...
متن کاملCharacterization of a Continuous Wave Laser for Resonance Ionization Mass Spectroscopy Analysis in Nuclear Forensics
متن کامل
Selective ionization of 2,4-xylenol in mass spectrometry using a tunable laser and supersonic jet technique.
A supersonic jet/resonance-enhanced multiphoton ionization/time-of-flight mass spectrum (SSJ/REMPI/TOF-MS) was measured for xylenols and ethylphenols. Sharp and intense peaks were observed in the REMPI spectrum of 2,4-xylenol, and the wavelength of the peak tentatively assigned to the 0-0 transition was the longest among xylenols and ethylphenols. These results suggest that 2,4-xylenol, designa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Atoms
سال: 2023
ISSN: ['2218-2004']
DOI: https://doi.org/10.3390/atoms11060088