On the Feasibility of Gap Detection of Power Transformer Partial Discharge UHF Signals: Gap Propagation Characteristics of Electromagnetic Waves

This study analyzed the transformer electromagnetic gap propagation characteristics. The influence of gap size is also analyzed, and the results experimentally verified. The obtained results indicated that the gap propagation characteristics of electromagnetic wave signals radiated by the partial discharge (PD) source in different directions are substantially different. The intensity of the ele...

متن کامل

Partial discharge signal detection using ultra high frequency method in high voltage power equipments: a review

Partial discharge (PD) can be detected using ultra high frequency (UHF) method to increase the detection threshold and to improve the performance of on-line measurement of PD in noise environment. The PD emitted energy as electromagnetic emission, acoustic emission and ozone and nitrous oxide gases. We can use this emitted energy to detected PD signal. The best method to detect PD in gas insula...

متن کامل

Suitability of Ultra High Frequency Partial Discharge Measurement for Quality Assurance and Testing of Power Transformers

Well known reasons for local failures in power transformers are caused by partial discharges (PD) in the electric insulation. Continuous deterioration over time increases the defect which finally can lead to a breakdown of the entire insulation. The importance of PD measurement is accommodated by standardized electrical measurement according to IEC 60270 [1] which is required for acceptance cer...

متن کامل

An Intelligent Sensor for the Ultra-High-Frequency Partial Discharge Online Monitoring of Power Transformers

Ultra-high-frequency (UHF) partial discharge (PD) online monitoring is an effective way to inspect potential faults and insulation defects in power transformers. The construction of UHF PD online monitoring system is a challenge because of the high-frequency and wide-frequency band of the UHF PD signal. This paper presents a novel, intelligent sensor for UHF PD online monitoring based on a new ...

متن کامل

Lumped Parameter Model for High Frequency Partial Discharge Estimation in High Voltage Transformer

Lumped Parameter Model is well known in solving high frequency signal propagation in high voltage transformer windings. At Southampton University, the modelling technique has been improvised and employed to solve partial discharge (PD) problem occurred within deep inside transformer windings. Firstly, a lumped capacitive parameter model was considered and secondly a transmission line lumped par...