Propagation and localisation of partial discharge in transformer bushing based on ultra‐high frequency technique
نویسندگان
چکیده
منابع مشابه
A Transformer Partial Discharge Measurement System Based on Fluorescent Fiber
Based on the physical phenomena of optical effects produced by the partial discharge (PD) and on the characteristics of fluorescent fiber sensing of weak fluorescent signals, a PD measurement system using a fluorescent fiber sensor was designed. The main parameters of the sensing system were calculated, an experimental testing platform for PD simulation in the lab was established, and PD signal...
متن کاملAn Ultrahigh Frequency Partial Discharge Signal De-Noising Method Based on a Generalized S-Transform and Module Time-Frequency Matrix
Due to electromagnetic interference in power substations, the partial discharge (PD) signals detected by ultrahigh frequency (UHF) antenna sensors often contain various background noises, which may hamper high voltage apparatus fault diagnosis and localization. This paper proposes a novel de-noising method based on the generalized S-transform and module time-frequency matrix to suppress noise i...
متن کاملa corpus-based study of the frequency of personal pronouns in translated and comparable non-translated persian texts
چکیده ندارد.
15 صفحه اولClassification of transformer faults using frequency response analysis based on cross-correlation technique and support vector machine
One of the most important methods for transformers fault diagnosis (especially mechanical defects) is the frequency response analysis (FRA) method. The most important step in the FRA diagnostic process is to differentiate the faults and classify them in different classes. This paper uses the intelligent support vector machine (SVM) method to classify transformer faults. For this purpose, two gr...
متن کاملOn-line Monitoring System Based on Principle of Electro-acoustic Monitoring for Transformer Partial Discharge
Partial discharge inside a transformer is mainly responsible for the insulation aging and damage of the transformer. However, partial discharge is usually accompanied by external signals like sound, light and electrical signals and detectable physical phenomena such as characteristical gas and dielectric loss. Therefore, it is of great significance to monitor online the external signals and phe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: High Voltage
سال: 2021
ISSN: 2397-7264,2397-7264
DOI: 10.1049/hve2.12075