Prone pulmonary artery catheter insertion aided by ultrasound
نویسندگان
چکیده
منابع مشابه
Ventricular asystole during pulmonary artery catheter insertion.
669 September 2015 A the overall pulmonary artery catheter (PAC) use has decreased, it remains a valuable tool in select patients. PAC insertion may result in ventricular or supraventricular dysrhythmias due to contact of the catheter with the cardiac chamber walls. The use of balloon-tipped catheters during insertion serves to increase the catheter tip surface area, thereby mitigating applied ...
متن کاملRight atrial membrane interfering with insertion of pulmonary artery catheter.
JH: Tourniquet infusion versus hyperthermic perfusion. Cancer 1982; 49:850–8 6. Krementz ET, Ryan RF, Carter RD, Sutherland CM, Reed RJ: Hyperthermic regional perfusion for melanoma of the limbs: cutaneous melanoma, Clinical Management and Treatment Results Worldwide. Edited by Balch CM, Milton GW. Philadelphia, JB Lippincott, 1985, pp 171–95 7. Klaase JM, Kroon BB, van Geel AN, Eggermont AM, F...
متن کاملAn unusual manifestation of pulmonary artery perforation during pulmonary artery catheter insertion.
P ULMONARY ARTERY balloon-tipped catheters are commonly inserted in critically ill patients as a source of physiologic data useful in planning management and evaluating the efficacy of treatment. Pulmonary artery perforation with resultant massive hemoptysis is a known complication of the use of these catheters, with an occurrence of 0.064% in one large series.’ The perforations with hemorrhage...
متن کاملThe pulmonary artery catheter.
Clinical Medicine Vol 2 No 2 March/April 2002 101 The flow-directed pulmonary artery catheter (PAC) has been in clinical use since its introduction by Swan and colleagues in 19701. During that time it has become widely used in critical care units throughout the world and is now the most commonly utilised form of flow monitoring. The haemodynamic data obtained with a PAC are used to monitor and ...
متن کاملPulmonary artery catheter-induced hemorrhage.
Pulmonary artery rupture by a flow-directed balloon-tipped catheter is a rare complication if guidelines for insertion of catheters are strictly applied. It should be stressed that the need for a "confirmed" wedge pressure should be weighed against the very real risk of this potentially fatal complication. Users of this catheter should expect and anticipate distal migration of the catheter tip....
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Anaesthesia
سال: 2001
ISSN: 0003-2409
DOI: 10.1111/j.1365-2044.2001.2094-17.x