Line Profile Measurement for SEM Imaging System
The performance of scanning electron microscope can be defined in terms of parameters such as the spatial resolution, and the signal to noise ratio of the image. Knowledge of these quantities is important in verifying that an instrument meets its specification, and subsequently for tracking and optimizing its performance during use. Analytical methods based on the power spectrum (2-D Fourier tr...
متن کاملA New Profile Measurement Method for Thin Film Surface
In order to measure the surface profile of the thin films in wide area with high accuracy, the research on the new measurement method was conducted and many patents on measurement method and system were researched. Based on the physical properties of soft thin film, the method of using white interferometer and ball cantilevers for measuring the surface profile of thin film is proposed. Then, th...
متن کاملNUMBER 6 Profile Measurement using Shadow Moiré
The purpose of this study is to perform profile measurements of human body parts using Shadow Moiré. The measurement results are used to assist medical personal in diagnosis and evaluation of patients. The system is composed only of low-cost standard optical components in order to turn it easily accessible for private offices. For automatic quantification of profiles the system combines Shadow ...
متن کاملAn Accurate Velocity Profile Measurement System for Microfluidics : a Direct Measurement of the Slip Length
We describe an accurate method to measure velocity profiles inside microchannels, using particle image velocimetry combined with a nano-positioning system. The experimental setup is used to measure the slip length for water flowing along an hydrophilic surface, pyrex glass, and an hydrophobic one, a monolayer of octadecyltrichlorosilane (OTS) over an atomically flat silicon substrate. In the py...
متن کاملBeam Profile Measurement with Optical Fiber Sensors at Flash
The system is intended to determine the beam profile at the DESY-FLASH undulator section as well as measuring beam losses with high spatial resolution. The measurement setup is based on wire scanners, optical fibers which are symmetrically mounted around the beam line over the full length (30 m) of the undulator section, a signal conditioning unit and a data acquisition system. The optical fibe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the Japan Society for Precision Engineering
سال: 1995
ISSN: 1882-675X,0912-0289