Pre-stretched Cuffs on Tracheostomy Tubes

in labour. It was subsequently calculated that less than half this amount of methoxyflurane was required for Caesarean section when using a 0.1% supplement. Cousins and Mazze (1972) qualified the findings that there was no evidence of nephrotoxicity following the use of 0.35% methoxyflurane in labour by stating: "The agent appears not to be nephrotoxic under most conditions of low dosage admini...

متن کامل

Pre-stretched cuffs on tracheostomy tubes.

in labour. It was subsequently calculated that less than half this amount of methoxyflurane was required for Caesarean section when using a 0.1% supplement. Cousins and Mazze (1972) qualified the findings that there was no evidence of nephrotoxicity following the use of 0.35% methoxyflurane in labour by stating: "The agent appears not to be nephrotoxic under most conditions of low dosage admini...

متن کامل

Interrupting gel layer between Double cuffs prevents fluid leakage past tracheal tube cuffs.

BACKGROUND Current tracheal tubes (TTs) cannot guarantee a perfect seal against pulmonary aspiration of upper airway secretions. The purpose of this study was to investigate whether a gel layer between the tracheal tube with double cuffs (Double cuffs) prevents fluid leakage past TT cuffs. METHODS In vitro fluid leakage tests were performed using the Double cuff with or without a gel layer be...

متن کامل

Comparison of microaspiration around TaperGuard tube cuffs and standard tracheal tubes in obese patients subjected to surgery under general anesthesia.

UNLABELLED Tracheal secretion leakage might lead to ventilator-associated pneumonia. Standard tracheal tube cuffs are cylindrical in shape. Bronchial tree aspiration is observed in the presence of leakage past tracheal tube cuffs. The new TaperGuard tracheal tube has a cuff in the shape of a cone, preventing from the development of microtubules and microaspiration. The aim of the study was to c...

متن کامل

The effects of cuffed endotracheal tubes on the tracheal wall.

Direct tracheoscopy was employed to assess tracheal damage following prolonged intubation. Comparison of conventional and low-pressure cuffs showed that there was less trauma from the low-pressure cuff. Comparison of tube sizes showed a reduction in injury with 8-mm diameter tubes compared with larger ones. Knowledge of tracheal damage following prolonged endotracheal intubation has depended hi...