Problems with blood gas analysis revisited.
نویسندگان
چکیده
منابع مشابه
SOLVING FUZZY LINEAR PROGRAMMING PROBLEMS WITH LINEAR MEMBERSHIP FUNCTIONS-REVISITED
Recently, Gasimov and Yenilmez proposed an approach for solving two kinds of fuzzy linear programming (FLP) problems. Through the approach, each FLP problem is first defuzzified into an equivalent crisp problem which is non-linear and even non-convex. Then, the crisp problem is solved by the use of the modified subgradient method. In this paper we will have another look at the earlier defuzzifi...
متن کاملArterial blood gas analysis.
With increasing use of arterial blood gas analysis in various ward and other hospital settings to aid medical diagnosis and management, nurses who can interpret results are often able to initiate earlier interventions and understand the reasons for medical interventions. This article enables nurses to interpret such results.
متن کاملsolving fuzzy linear programming problems with linear membership functions-revisited
recently, gasimov and yenilmez proposed an approach for solving two kinds of fuzzy linear programming (flp) problems. through the approach, each flp problem is first defuzzified into an equivalent crisp problem which is non-linear and even non-convex. then, the crisp problem is solved by the use of the modified subgradient method. in this paper we will have another look at the earlier defuzzifi...
متن کاملWard-based blood gas analysis.
Blood gas analysis is a time-consuming procedure, taking up to 30 minutes from obtaining a blood sample from the patient to receiving the results. The process can involve as many as three health care professionals: the doctor, nurse and a member of the pathology department. The result is that it is difficult to provide continual monitoring of blood gas levels on patients with acute respiratory ...
متن کاملBlood Gas Analysis and Acid–base Disturbances
V . O2 is identical to tissue V . O2. This is extremely diffi cult to achieve clinically, particularly in mechanically ventilated subjects. Also determination of V . O2 becomes progressively less accurate as FIO2 increases. Various alternative means of measuring V . O2 which overcome some of these diffi culties are available and may be more appropriate for clinical use. For example, a pneumotac...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Clinical Chemistry
سال: 1987
ISSN: 0009-9147,1530-8561
DOI: 10.1093/clinchem/33.5.719