Problems on internal dose assessment due to iodine-129 through crops.
نویسندگان
چکیده
منابع مشابه
Assessment of dose equivalent due to neutrinos.
Neutrinos are present in the natural environment and are also produced by particle accelerators. A recent hypothesis has also been proposed that asserts that ionizing radiation due to neutrinos from certain astronomical events may have led to the extinction of some biological species. Thus, it is of interest to be able to estimate the dose equivalent due to these weakly interacting particles. P...
متن کاملAssessment of Effective Dose Equivalent from Internal Exposure to 222Rn in Ramsar City
Introduction In this study, effective dose equivalent for the public due to internal exposure to 222radon (222Rn) was evaluated in three regions of Ramsar, a northern coastal city in Iran. Materials and Methods Measurements were carried out using a radon monitoring device. Outdoor and indoor radon concentrations were measured within 24 hours with an integration in...
متن کاملAssessment of secondary neutron dose due to dental restorations in head and neck radiation therapy
Introduction: One of scientific concern is increasing of unwanted neutron dose to the patient, in head and neck radiation therapy due to the presence of some isotopes in dental restorations and head of medical linac. The aim of this study is to measure the equivalent dose of thermal and fast neutron due to head of Siemens Primus Linac and a healthy tooth, Amalgam, Ni-Cr alloy a...
متن کاملAssessment the Effect of Kidney Internal Structure on Gamma Absorbed Dose of Radiopharmaceutical 111In-DTPA
Large quantities of radiopharmaceuticals prescribed for treatment and diagnosis are excreted through kidney. Therefore, radiation unwanted dose is created in kidney. As a result, exact calculation of prescribed radiopharmaceuticals amount is important. Monte Carlo method is used for simulation of radiation transport in body due to random nature of radiation. In this research, for the first time...
متن کاملAssessment the Effect of Kidney Internal Structure on Gamma Absorbed Dose of Radiopharmaceutical 111In-DTPA
Large quantities of radiopharmaceuticals prescribed for treatment and diagnosis are excreted through kidney. Therefore, radiation unwanted dose is created in kidney. As a result, exact calculation of prescribed radiopharmaceuticals amount is important. Monte Carlo method is used for simulation of radiation transport in body due to random nature of radiation. In this research, for the first time...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the Atomic Energy Society of Japan / Atomic Energy Society of Japan
سال: 1985
ISSN: 0004-7120
DOI: 10.3327/jaesj.27.388