Probing Electrode Structure Using Electrochemical Impedance Spectroscopy

نویسندگان

چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reducing Impedance Fluctuation by Electrode Structure for Electrochemical Impedance Spectroscopy

In this paper, we investigated the electrode structure of the electrical bio-sensor to reduce impedance measurement fluctuation. Five pairs of the same electrodes were formed on the PCB substrate, and a fluidic channel was constructed with a double-sided tape and polycarbonate cover so that all the electrodes had the same reagent distribution. In order to find an electrode structure with little...

متن کامل

Using electrochemical impedance spectroscopy of salicylate anion selective electrode: simulation for behavior of electrode

In this paper, the behavior of the salicylate anion-selective electrode was studied using the electrochemical impedance spectroscopy technique. Considering the diagram of the charge transfer resistance and -logarithm of the double layer capacitance versus -logarithm of the concentration, linear range concentration increased to 1.0×10^{-8}-1.0×10^{-1} M and 1.0×10^{-9}-1.0×10^{-1} M, respectivel...

متن کامل

Probing the responsive behavior of polyelectrolyte brushes using electrochemical impedance spectroscopy.

Cyclic voltammetry and impedance spectroscopy were employed to probe the responsive properties of polyelectrolyte brushes. Poly[(dimethylamino)ethyl methacrylate] (PDMAEMA) brushes over 100 nm thick on gold substrates were synthesized via surface-initiated atom-transfer radical polymerization and quaternized with methane iodide to obtain cationic brushes (Q-PDMAEMA). Q-PDMAEMA brushes respond t...

متن کامل

Label-Free Aptasensor for Lysozyme Detection Using Electrochemical Impedance Spectroscopy

This research develops a label-free aptamer biosensor (aptasensor) based on graphite-epoxy composite electrodes (GECs) for the detection of lysozyme protein using Electrochemical Impedance Spectroscopy (EIS) technique. The chosen immobilization technique was based on covalent bonding using carbodiimide chemistry; for this purpose, carboxylic moieties were first generated on the graphite by elec...

متن کامل

Determining detection limits of aqueous anions using electrochemical impedance spectroscopy

Background: Pulsed amperometric detection is a relatively new method for detection of ions and especially nonelectrolytes such as carbohydrates in aqueous solutions. Pulsed amperometric detection relies on a redox reaction while electrochemical impedance simply measures the real and capacitive resistant of the solution. There is a correlation between the real impedance of a solution and the ion...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: ECS Proceedings Volumes

سال: 2002

ISSN: 0161-6374,2576-1579

DOI: 10.1149/200231.0257pv