Probing Electrode Structure Using Electrochemical Impedance Spectroscopy
نویسندگان
چکیده
منابع مشابه
Reducing Impedance Fluctuation by Electrode Structure for Electrochemical Impedance Spectroscopy
In this paper, we investigated the electrode structure of the electrical bio-sensor to reduce impedance measurement fluctuation. Five pairs of the same electrodes were formed on the PCB substrate, and a fluidic channel was constructed with a double-sided tape and polycarbonate cover so that all the electrodes had the same reagent distribution. In order to find an electrode structure with little...
متن کاملUsing electrochemical impedance spectroscopy of salicylate anion selective electrode: simulation for behavior of electrode
In this paper, the behavior of the salicylate anion-selective electrode was studied using the electrochemical impedance spectroscopy technique. Considering the diagram of the charge transfer resistance and -logarithm of the double layer capacitance versus -logarithm of the concentration, linear range concentration increased to 1.0×10^{-8}-1.0×10^{-1} M and 1.0×10^{-9}-1.0×10^{-1} M, respectivel...
متن کاملProbing the responsive behavior of polyelectrolyte brushes using electrochemical impedance spectroscopy.
Cyclic voltammetry and impedance spectroscopy were employed to probe the responsive properties of polyelectrolyte brushes. Poly[(dimethylamino)ethyl methacrylate] (PDMAEMA) brushes over 100 nm thick on gold substrates were synthesized via surface-initiated atom-transfer radical polymerization and quaternized with methane iodide to obtain cationic brushes (Q-PDMAEMA). Q-PDMAEMA brushes respond t...
متن کاملLabel-Free Aptasensor for Lysozyme Detection Using Electrochemical Impedance Spectroscopy
This research develops a label-free aptamer biosensor (aptasensor) based on graphite-epoxy composite electrodes (GECs) for the detection of lysozyme protein using Electrochemical Impedance Spectroscopy (EIS) technique. The chosen immobilization technique was based on covalent bonding using carbodiimide chemistry; for this purpose, carboxylic moieties were first generated on the graphite by elec...
متن کاملDetermining detection limits of aqueous anions using electrochemical impedance spectroscopy
Background: Pulsed amperometric detection is a relatively new method for detection of ions and especially nonelectrolytes such as carbohydrates in aqueous solutions. Pulsed amperometric detection relies on a redox reaction while electrochemical impedance simply measures the real and capacitive resistant of the solution. There is a correlation between the real impedance of a solution and the ion...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: ECS Proceedings Volumes
سال: 2002
ISSN: 0161-6374,2576-1579
DOI: 10.1149/200231.0257pv