Primary Stability of Revision Acetabular Reconstructions Using an Innovative Bone Graft Substitute: A Comparative Biomechanical Study on Cadaveric Pelvises

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Effect of Bone Marrow Graft on Bone Healing: A Radiological and Biomechanical Study

Background: There are multiple methods for acceleration of bone healing. Bone marrow has been shown to contain osteoprogenitor cells. Objective: To determine the effect of percutaneous bone marrow injection on bone healing. Methods: 15 mature, 2-kg-weighing white New Zealand rabbits from both sexes were randomized into 3 groups: Group I: Only osteotomy of right radius was performed and a 5 mm b...

متن کامل

Femoral component revision using impacted morsellised cancellous graft. A biomechanical study of implant stability.

We have tested the axial and torsional stability of femoral components after revision arthroplasty in a cadaver model, using impacted morsellised cancellous graft and cement. Each one of six matched pairs of fresh frozen human femora had either a primary or a revision prosthesis cemented in place. For the 'revision' experiments, all cancellous bone was removed from the proximal femur which was ...

متن کامل

Biomechanical Analysis of Acetabular Revision Constructs

Pelvic discontinuity in revision total hip arthroplasty presents problems with component fixation and union. A construct was proposed based on bicolumnar fixation for transverse acetabular fractures. Each of 3 reconstructions was performed on 6 composite hemipelvises: (1) a cup-cage construct, (2) a posterior column plate construct, and (3) a bicolumnar construct (no. 2 plus an antegrade 4.5-mm...

متن کامل

Assessing the Acetabular Cup Implant Primary Stability by Impact Analyses: A Cadaveric Study

BACKGROUND The primary stability of the acetabular cup (AC) implant is an important determinant for the long term success of cementless hip surgery. However, it remains difficult to assess the AC implant stability due to the complex nature of the bone-implant interface. A compromise should be found when inserting the AC implant in order to obtain a sufficient implant stability without risking b...

متن کامل

Traumatic Periprosthetic Acetabular Fracture Treated with One-Stage Exchange and Bone Reconstruction Using a Synthetic Bone Graft Substitute

A case of a traumatic periprosthetic acetabular fracture in an elderly patient, which was treated by one-stage hip exchange with implantation of an antiprotrusio cage and reconstruction of the acetabular bone loss with an injectable calcium sulphate/hydroxyapatite bone graft substitute, is reported. The paste-like bone graft substitute was injected through the holes of the antiprotrusio cage. A...