Primary accelerometer calibration with two-axis automatic positioning stage
نویسندگان
چکیده
In this study, we developed an automated, multipoint primary accelerometer calibration system using a two-axis positioning stage and heterodyne laser interferometer. The proposed offers low-cost, convenient, automated calibration, enabling less lead time. also better repeatability of 1μm, which is impossible through manual alignments. We measured the surface deformation reflection adaptor for single-ended by measuring more than 450 measurement positions. Visualizing surfaces facilitates understanding effects or non-linear motion, are among most significant uncertainty components in high-frequency calibrations.
منابع مشابه
Comprehensive Calibration of Strap-Down Tri-Axis Accelerometer Unit
Xi Zhang 1,2, Jie Li 1,3,*, Li Qin 1,3 and Chong Shen 3,4 1 National Key Laboratory for Electronic Measurement Technology, North University of China, Taiyuan 030051, China; [email protected] (X.Z.); [email protected] (L.Q.) 2 School of Computer Science and Control Engineering, North University of China, Taiyuan 030051, China 3 School of Instrument and Electronics, North University of China, Tai...
متن کاملAccelerometer for Mobile Robot Positioning
An evaluation of a low-cost, small sized solid state accelerometer is described in this paper. The sensor is intended for positioning of a mobile robot or platform. Acceleration signal outputted by the sensor is doubly integrated with time which yields the traveled distance. Bias offset drift exhibits in the acceleration signal is accumulative and the accuracy of the distance measurement deteri...
متن کاملAutomatic Calibration of Large-scale WiFi-Positioning Systems
The growing market for location-based services causes a great demand for positioning systems with high accuracy. In addition to GPS, there are several WiFi positioning systems which allow a cost-effective indoor and outdoor positioning. But despite the fact that they provide accurate measurements in indoor environments, their outdoor performance is not as good as with GPS. This is due to the fa...
متن کاملA Two-Stage Design with Two Correlated Co-Primary Endpoints
Simon two-stage design is often applied to phase II singlearm oncology trials where a binary outcome is of interest [2]. The trial design allows us to explore potential efficacy and safety signals quickly while limiting the number of patients exposed to an inefficacious new treatment. In the well-known Simon two stage design, hypotheses are typically set up as H : P P = vs. : A A H P P = , wher...
متن کاملTwo-stage DEA with Fuzzy Data
Data envelopment analysis is a nonparametric technique checking efficiency of DMUs using math programming. In conventional DEA, it has been assumed that the status of each measure is clearly known as either input or output. Kao and Hwang (2008) developed a data envelopment analysis (DEA) approach for measuring efficiency of decision processes which can be divided into two stages. The first stag...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Measurement
سال: 2022
ISSN: ['1873-412X', '0263-2241']
DOI: https://doi.org/10.1016/j.measurement.2022.112044