Prevention of the current transformer saturation by using negative resistance

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Current Transformer Saturation Detection Using Gaussian Mixture Models

This paper presents a novel current transformer (CT) saturation detection approach based on Gaussian Mixture Models (GMMs). High accuracy is the advantage of this method. GMMs are trained with secondary current of CT. The appropriate performance of the proposed method is tested by simulation of different fault conditions in PSCAD/EMTDC software. The results show that the trained GMMs can succes...

متن کامل

Artificial Intelligence Based Approach for Identification of Current Transformer Saturation from Faults in Power Transformers

Protection systems have vital role in network reliability in short circuit mode and proper operating for relays. Current transformer often in transient and saturation under short circuit mode causes mal-operation of relays which will have undesirable effects. Therefore, proper and quick identification of Current transformer saturation is so important. In this paper, an Artificial Neural Network...

متن کامل

examining the relationship between fear of negative evaluation and communication strategies by iranian efl learners

the purpose of the present study was to investigate the relationship between fear of negative evaluation (fne) and communication strategies (css) among iranian efl learners. it was aimed to examine the differences in the use of communication strategies between speakers with high or low degree of fear of negative evaluation. the current study was a case study consisting of 10 english learners at...

Mitigation Transformer Inrush Current Using Modified Transient Current Limiter

This study presents a modified transient current limiter (MTCL) for mitigation the inrush current of transformers. The MTCL is based on conventional transient current limiter (TCL), which, its configuration is modified to overcome the TCL drawbacks of operation. The proposed MTCL offers lower power losses and voltage/current THD during normal operation mode. It needs only one limiting reactor i...

متن کامل

Current Transformer Saturation Detection By Wavelet Transform and Compensation By Newton’s Forward Interpolation

-Protective systems require a faithful reproduction of primary current on the Current Transformer (CT) secondary side. Saturation is a common problem in a steel core CT. Saturation problem causes dreadful effects in the protection systems. This paper presents a simple solution towards detection and compensation of current transformer saturation problems. This paper describes a method in which C...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IET Generation, Transmission & Distribution

سال: 2020

ISSN: 1751-8687,1751-8695

DOI: 10.1049/gtd2.12038