Prestressing Effect of LNG Storage Tank with 2,400 MPa High-Strength Strands
نویسندگان
چکیده
منابع مشابه
Corrosion Performance of Prestressing Strands in Contact with Dissimilar Grouts
To improve the corrosion protection provided to prestressing strands, anti-bleed grouts are used to fill voids in post-tensioning ducts that result from bleeding and shrinkage of older portland cement grouts. Environmental differences caused by exposing the strands to dissimilar grouts, however, have the potential to cause rapid corrosion. Portland cement grout, gypsum grout, and four commercia...
متن کاملPull-Out Strength and Bond Behavior of Prestressing Strands in Prestressed Self-Consolidating Concrete
With the extensive use of self-consolidating concrete (SCC) worldwide, it is important to ensure that such concrete can secure uniform in-situ mechanical properties that are similar to those obtained with properly consolidated concrete of conventional fluidity. Ensuring proper stability of SCC is essential to enhance the uniformity of in-situ mechanical properties, including bond to embedded re...
متن کاملSome Problems on High Strength Concrete for Prestressing by
Some Problems on High Strength Concrete for Prestressing by Kanji YAMAZAKI (Research Laboratory of Nihon Cement Co., Ltd., Tokyo) This paper describes some problems on high strength concrete studied in our laboratory in recent years. Summary of this report is as follows: (1) In order to make high strength concrete for prestressing, it is necessary to lower the water-cement ratio. But, in the ca...
متن کاملAcoustic Emission use for prestressing strands corrosion assessment
Acoustic emission (AE) is studied to monitor stress corrosion cracking (SCC) of prestressing strands. This nondestructive method seems particularly recommended because it has the capacity to realize a real time and a remote detection of active defects. In this study corrosion mechanisms are generated in an accelerated way. A particular attention has been made on hydrogen embrittlement process b...
متن کاملStorage Tank Design
A calculus problem arising in the operation of a storage tank for a chemical processing plant is described. Constructing an appropriate gauge for the storage tank requires computing the volume of water residing inside a tilted cylindrical pipe. The following calculus problem arose in the engineering design of a storage tank facility, and is possibly more interesting and challenging for students...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of The Korean Society of Civil Engineers
سال: 2016
ISSN: 1015-6348
DOI: 10.12652/ksce.2016.36.6.0999