Prestress Loss Test and Analysis of Long Span Continuous Rigid Frame Bridge

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Technology Research Status Review of Long-span Continuous Rigid Frame Bridge Deck Pavement

Through the analysis and summary of research status and development trends of deck pavement technology of long-span continuous rigid frame bridge deck pavement at home and abroad, the impact factors of durability of continuous rigid frame bridge deck pavement, such as design flaw, constructional quality and overload are studied. This article will comprehensively analyze the cause of disease foc...

متن کامل

Computer Simulation of Buffeting Responses for Long-span Continuous Rigid-frame Bridge with Over-height Pier

The continuous rigid frame bridges are more sensitive to wind action with the increase of bridge span and pier height. In order to calculate the wind induced buffeting responses, the fluctuating wind field at bridge site are simulated by harmonic synthesis method and the wind loads are also derived based on the simplified quasi-steady theory, the time-history dynamic responses of the bridge are...

متن کامل

Analytical Research on Deformation Monitoring of Large Span Continuous Rigid Frame Bridge during Operation

Based on a large span continuous rigid frame bridge in Chongqing of China, the main pier vertical displacement and deviation, the bridge deck alignment and the expansion joint deformation are analytically researched during operation. Firstly, the monitoring content and method of the large span continuous rigid frame bridge are clearly stated. Secondly, by finite element software Midas Civil, th...

متن کامل

Damage Identification of Continuous Rigid Frame Concrete Bridge

During a bridge service life, many factors can cause damage accumulation such as overloaded traffic, fatigue effect, and so on. Hence, the identification of potential damages has been received wide attention to prevent such sudden fatal accident. An experiment of a continuous rigid frame concrete bridge, which had 3 spans and a total length of 18 meters, was presented in this paper. Two load st...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: DEStech Transactions on Materials Science and Engineering

سال: 2017

ISSN: 2572-889X

DOI: 10.12783/dtmse/icmsea/mce2017/10841