Pressure Sensor Calibration for Measuring Stud-player Impacts
نویسندگان
چکیده
منابع مشابه
Pressure sensor calibration for measuring stud-player impacts
In rugby union, laceration injuries can occur from players stamping on opponents in the ruck. To measure the stud-skin interaction during stamping movements, pressure sensors can be used. Pressure sensor calibration techniques have highlighted the need to perform calibrations using appropriate impact dynamics. A pilot study with seven rugby players informed the expected peak forces and loading ...
متن کاملA fiber optic sensor for measuring glucose in aqueous solutions
In this paper, the set-up of a multi-mode fiber optic sensor for measuring glucose in aqueous solutions is investigated and evaluated. The basis of this sensor is based on the Fresnel Reflection. In this setup, a helium-neon laser is used as a light source, a fiber optic probe, photocell as detector and a digital multimeter. The statistical analysis of the recorded data shows a highly linear be...
متن کاملMiniaturized Fiber Optic Sensor for Measuring Intervertebral Disc Pressure
This paper reports the development of a miniature fiber optic pressure sensor system for in vitro intradiscal pressure measurements for rodents. The primary focus of this work is the design and fabrication of a sensor element with a multi-layer polymer-metal diaphragm. This diaphragm consists of a base polyimide layer (150 nm thick), a metal reflective layer (1 μm thick), and another polyimide ...
متن کاملDynamic Tire Pressure Sensor for Measuring Ground Vibration
This work presents a convenient and non-contact acoustic sensing approach for measuring ground vibration. This approach, which uses an instantaneous dynamic tire pressure sensor (DTPS), possesses the capability to replace the accelerometer or directional microphone currently being used for inspecting pavement conditions. By measuring dynamic pressure changes inside the tire, ground vibration ca...
متن کاملMetrical Calibration of a Phase Measuring Triangulation Sensor
Metrical calibration is very critical for the accuracy of a 3d sensor. Measuring uncertainty of about 1:3000 of the z-range requires a calibration accuracy of about 1:10. Several model-based approaches for this problem exist. In this article the calibration task for a phase measuring triangulation sensor is described. After a short description of the geometrical distortions that are compensated...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Procedia Engineering
سال: 2016
ISSN: 1877-7058
DOI: 10.1016/j.proeng.2016.06.273