<p>Repeatability and Interchangeability of Topometric, Anterior Chamber and Corneal Wavefront Data Between Two Scheimpflug Camera Devices</p>

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Anterior chamber depth measurement: interchangeability between Pentacam and other devices

We reviewed a series of recently published studies in which the anterior chamber depth (ACD) distance was measured by Pentacam or Pentacam HR and compared with other measuring devices. Since some published studies reach contradictory conclusions regarding device interchangeability and include di erent ocular conditions, for instance, phakic eyes, pseudophakic eyes, cataractous eye, and so on, t...

متن کامل

Central corneal thickness and anterior chamber depth measurement by Sirius® Scheimpflug tomography and ultrasound

BACKGROUND The purpose of this study was to compare the accuracy of the new Sirius(®) Scheimpflug anterior segment examination device for measurement of central corneal thickness (CCT) and anterior chamber depth (ACD) with that of CCT measurements obtained by ultrasound pachymetry and ACD measurements obtained by ultrasound biometry, respectively. METHODS CCT and ACD was measured in 50 right ...

متن کامل

Comparison between Two Scheimpflug Anterior Segment Analyzers

PURPOSE To compare the anterior segment indices measured by two Scheimpflug camera machines; Galilei and Pentacam. METHODS In this observational case series, the anterior segment indices of myopic healthy subjects seeking for refractive surgery were measured by Pentacam and Galilei on the same day. Analyzed parameters were anterior and posterior best fit spheres (BFS), axial curvature, true c...

متن کامل

Measurements of anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter using two Scheimpflug imaging devices.

PURPOSE To compare the ocular anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter, as measured with two different Scheimpflug imaging devices. METHODS This transversal study included 80 right eyes from 80 subjects aged from 20 to 40 years. Their spherical equivalents ranged from -4.25 to +1.00 diopters (D). Each eye's anterior chamber depth, white-to-wh...

متن کامل

Assessment of anterior and posterior corneal indices using two Scheimpflug analyzers.

PURPOSE To assess the agreement between the elevation and curvature measurements of the anterior and posterior corneal surfaces obtained using the Galilei Dual Scheimpflug Analyzer and those obtained using the Pentacam single Scheimpflug system. METHODS This prospective, noninterventional, diagnostic study was conducted at the Department of Ophthalmology at the American University of Beirut (...