Preparative fractionation of DNA restriction fragments by reversed phase column chromatography.

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Preparative fractionation of DNA restriction fragments by reversed phase column chromatography.

Reversed phase column chromatography on RPC-5 resin was used to fractionate milligram quantities of DNA fragments generated by restriction endonucleases. Fractionation was on the basis of size, the presence or absence of sticky ends, and at least one as yet undertermined property.

متن کامل

Separation of Somatropin and Its Degradation Products by High-Performance Liquid Chromatography Using a Reversed-Phase Polymeric Column

The accurate prediction of protein stability is one of the most challenging goals in protein formulation and delivery. In this study, a gradient RP-HPLC method is described for the separation of human growth hormone (hGH) variants as deamidated and oxidized forms. The methodology employed a polymeric poly (styrene-co-divinylbenzene) column and a 1mL/min flow rate of a linear gradient of 0.1% v/...

متن کامل

Separation of Somatropin and Its Degradation Products by High-Performance Liquid Chromatography Using a Reversed-Phase Polymeric Column

The accurate prediction of protein stability is one of the most challenging goals in protein formulation and delivery. In this study, a gradient RP-HPLC method is described for the separation of human growth hormone (hGH) variants as deamidated and oxidized forms. The methodology employed a polymeric poly (styrene-co-divinylbenzene) column and a 1mL/min flow rate of a linear gradient of 0.1% v/...

متن کامل

Determination of bethanidine in plasma by liquid-chromatography with a microbore reversed-phase column.

In this novel method for quantifying bethanidine in plasma, after a multi-step extraction of bethanidine and internal standard from 2.0 mL of plasma, the drugs are separated on a "microbore" C18 reversed-phase column and quantified by their ultraviolet absorbance at 210 nm. The isocratic chromatographic separation takes about 15 min with use of an ion-pairing regent in the mobile phase (acetate...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Proceedings of the National Academy of Sciences

سال: 1976

ISSN: 0027-8424,1091-6490

DOI: 10.1073/pnas.73.9.3117