Preparation of the Silicone-Modified Antimicrobial Polyethylene Endotracheal Tube (PE ETT)
نویسندگان
چکیده
منابع مشابه
The Oropharyngeal Bacterial Colonization of Patients with Endotracheal Tube
Abstract Background and Objective: Bacterial colonization in upper respiratory airways is one of the major risk factors for the development of the ventilator–associated pneumonia (VAP), which is the most common and serious hospital-acquired infection in intensive care unit (ICU). The aim of this study was to determine the frequency of oropharyngeal microorganisms of patients with tracheal t...
متن کاملEndotracheal tube extubation force: adhesive tape versus endotracheal tube holder.
BACKGROUND Adhesive tape is commonly used to secure the endotracheal tube (ETT) in anesthesia and intensive-care settings. OBJECTIVE To determine the force required to extubate when the ETT is secured with adhesive tape or commercially available ETT holders. METHODS We orally intubated a simulation manikin with a standard 8.0-mm inner-diameter ETT, inflated the cuff to 20 cm H(2)O, and mea...
متن کاملPreparation and Characterization of Modified Soda Lignin with Polyethylene Glycol
Soda lignin does not have thermal flowing characteristics and it is impossible for it to be further thermally molded. To achieve the fusibility of soda lignin for fiber preparation by melt-spinning, an effective method for soda lignin modification was conducted by cooking it with polyethylene glycol (PEG) 400 at various ratios. The higher the ratio of PEG that was used, the more PEG molecular c...
متن کاملThe Rottenrow endotracheal tube holder.
Case 3 is a rare congenital abnormality of the inner ear which usually presents as recurrent meningitis. This abnormality is now well documented.4 It should be suspected as a cause of recurrent meningitis in a child who has a sensorineural deafness. The presence of fluid behind the tympanic membrane should make one suspicious and the diagnosis can be confirmed by tomograms of the inner ear. The...
متن کاملConfirming Endotracheal Tube (ETT) Position in Pediatric and Neonatology Using a Bedside Ultrasound (Us); an Emerging Tool
US have a promising alternative mean for quick confirmation of the ETT placement. However, small and few studies have shown that the sensitivity of this tool to accurately assess the ETT placement relative to chest XR or capnography is approximately 91-100%. The overall accuracy of this method is very interesting as it reaches 89-98% in some studies. An additional advantage of this method as su...