Preliminary use of a double-echo pulse sequence with 3D ultrashort echo time in the MRI of bones and joints
The aim of the present study was to investigate the application of a double-echo pulse sequence with 3D ultrashort echo time (UTE) in the magnetic resonance imaging (MRI) of bones and joints. In total, 7 healthy volunteers and 1 volunteer with a suspected tear of the lateral meniscus of the left knee joint underwent MRI with a double-echo pulse sequence and 3D UTE. The imaging was performed on ...
متن کاملOptimized 3D ultrashort echo time pulmonary MRI.
PURPOSE To optimize 3D radial ultrashort echo time MRI for high resolution whole-lung imaging. METHODS 3D radial ultrashort echo time was implemented on a 3T scanner to investigate the effects of: (1) limited field-of-view excitation, (2) variable density readouts, and (3) radial oversampling. Improvements in noise performance and spatial resolution were assessed through simulation and phanto...
متن کاملComparison of Three-Dimensional Double-Echo Steady-State Sequence with Routine Two-Dimensional Sequence in the Depiction of Knee Cartilage
Introduction: There are some routine two-dimensional sequences, including short tau inversion recovery (STIR), T2-weighted fast-spin echo (T2W-FSE), and proton-density fast spin-echo for diagnosing osteoarthritis and lesions of the knee cartilage. However, these sequences have some disadvantages, such as long scan time, inadequate spatial resolution, and suboptimal tis...
متن کاملQuantitative contrast-enhanced MRI with superparamagnetic nanoparticles using ultrashort time-to-echo pulse sequences.
PURPOSE Conventional MRI using contrast agents is semiquantitative because it is inherently sensitive to extravoxular susceptibility artifacts, field inhomogeneity, partial voluming, perivascular effects, and motion/flow artifacts. Herein we demonstrate a quantitative contrast-enhanced MRI technique using ultrashort time-to-echo pulse sequences for measuring clinically relevant concentrations o...
متن کاملMRI with zero echo time: hard versus sweep pulse excitation.
Zero echo time can be obtained in MRI by performing radiofrequency (RF) excitation as well as acquisition in the presence of a constant gradient applied for purely frequency-encoded, radial centre-out k-space encoding. In this approach, the spatially nonselective excitation must uniformly cover the full frequency bandwidth spanned by the readout gradient. This can be accomplished either by shor...