Preliminary Studies of Perovskite-Loaded Plastic Scintillator Prototypes for Radioactive Strontium Detection

نویسندگان

چکیده

Functional plastic scintillators have attracted much attention for their usefulness in on-site monitoring and detection environments. In this study, we elucidated a highly reliable functional scintillator of radioactive strontium, which means potent perovskite-loaded polymeric scintillation material based on epoxy 2,5-diphenyloxazole (PPO). Moreover, Monte Carlo N-Particle (MCNP) simulation was performed to optimize the thickness efficient strontium detection. A 2 mm found be optimum beta-ray newly developed with 430 nm emission from perovskite loading could trigger enhancement employing potential indication energy transfer into photomultiplier (PMT) detector. Furthermore, response emitter 90Sr compared commercial BC-400 by exhibiting efficiency spectrum fabricated scintillator. We believe that suggested employed as radiation detector wide range applications including decommissioning sites nuclear facilities, security monitoring, nonproliferation, safeguards.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Studies of Bone Metabolism with the Aid of Radioactive Strontium

STUDIES OF BONE lWABOLISM WITH THE AID OF RADIOACTIVE STRONTIUM by D. e. JonesandD. H. Copp,M.D. January16T 1948 The kinetics of skeletal uptake and urinary excretion of radiostrontium were studied during the critieal first hour following intraperitoneal injection of a carrier-free dose. These experiments not only provided valuable data con.cerning the metabolism and fixation of this important ...

متن کامل

Comparative analysis of pulse shape discrimination methods in a Li loaded plastic scintillator

Three algorithms for discriminating between fast neutrons, thermal neutrons and gamma rays in a Li loaded plastic scintillator have been compared. Following a literature review of existing pulse shape discrimination techniques, the performance of the charge comparison method, triangular filtering and frequency gradient analysis were investigated in this work. The scintillator was exposed to thr...

متن کامل

Synthesis and Characterization of γ-MnO2-AgA Zeolite Nanocomposite and its Application for the Removal of Radioactive Strontium-90 (90Sr)

In this scientific research, for the first time, the removal of radioactive strontium-90 (90Sr) by γ-MnO2-AgA zeolite as a novel nanocomposite adsorbent was accomplished under different conditions such as pH, temperature, adsorbent amount and the contact time that are examined from drinking water of Ramsar city and monitored via Ultra Low-Level Liquid Scintillation Counting (LSC) technique. Pri...

متن کامل

Preparation of nanocomposite scintillator of ZnS doped with Ag, Cu and AgCu for alpha particle detection

ZnS nanoparticles (NPs) doped with ‎Ag‎, ‎Cu‎, ‎and AgCu were synthesized using hydrothermal‎ ‎method in water solution‎. ‎The NPS are characterized by X-ray diffraction (XRD)‎, ‎energy-dispersive‎ ‎X-ray spectroscopy scanning (EDX)‎, ‎scanning electron‎ ‎microscopy (SEM) and dynamic light scattering (DLS)‎. ‎The produced NPs have approximately hexagonal structure and a cubic zinc blended struc...

متن کامل

Layered metal sulfides: exceptionally selective agents for radioactive strontium removal.

In this article, we report the family of robust layered sulfides K(2x)Mn(x)Sn(3-x)S(6) (x = 0.5-0.95) (KMS-1). These materials feature hexagonal [Mn(x)Sn(3-x)S(6)](2x-) slabs of the CdI(2) type and contain highly mobile K(+) ions in their interlayer space that are easily exchangeable with other cations and particularly strontium. KMS-1 display outstanding preference for strontium ions in highly...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Chemosensors

سال: 2021

ISSN: ['2227-9040']

DOI: https://doi.org/10.3390/chemosensors9030053