Preliminary Evaluation of the Vitros ECi Cardiac Troponin I Assay

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analytical performance of the i-STAT cardiac troponin I assay.

BACKGROUND This study determines the analytical characteristics of the i-STAT cardiac troponin I assay (cTnI; i-STAT, Princeton, NJ), a 10-min POC assay, designed to be performed at the bedside. METHODS Three different hospitals participated in a patient specimen and analytical validation study (n=186) for the i-STAT cTnI assay carried out in real time. A total of 186 whole blood specimens (l...

متن کامل

Evaluation of cardiac troponin I stability

ve markers of cardiovascular mortality, notably in patients undergoing vascular surgery3, non-cardiac surgery4, traumatic cardiac injury5 or in pregnant women suffering from pre-eclampsia6. Cardiac troponins are thus extensively prescribed in various clinical situations, and their analysis must be carried in appropriate conditions to reach the highest possible accuracy. In France, to reach opti...

متن کامل

Evaluation of the AccuTnI cardiac troponin I assay for risk assessment in acute coronary syndromes.

Risk Assessment in Acute Coronary Syndromes, David A. Morrow, Nader Rifai, Marc S. Sabatine, Shake Ayanian, Sabina A. Murphy, James A. de Lemos, Eugene Braunwald, and Christopher P. Cannon ( Department of Medicine and TIMI Study Group, Brigham & Women’s Hospital, 75 Francis St., Boston, MA 02115; 2 Children’s Hospital Medical Center, 300 Longwood Ave., Boston, MA 02115; and 3 Donald W. Reynolds...

متن کامل

Biologic variation of a novel cardiac troponin I assay.

Cardiac troponin is the marker of choice for evaluating myocardial injury (1 ). High-sensitivity assays improve analytical detection limits, thereby allowing concentrations to be measured in the majority of healthy individuals. This capability allows an assessment of biologic variation (BV) to determine what constitutes an important change in the cardiac troponin concentration, a critical metri...

متن کامل

Highly sensitive cardiac troponin I assay leads to lowered specificity.

I read with great interest the article of Kavsak et al. (1 ) on the utility of a next-generation high-sensitivity Beckman Coulter cardiac troponin I (cTnI) assay with a 20% CV at 2.95 ng/L. This approach demonstrated a higher diagnostic sensitivity (81% vs 62%) for myocardial injury with a changing pattern of cTnI values, compared with the AccuTnI assay cleared by the US Food and Drug Administr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Clinical Chemistry

سال: 2000

ISSN: 0009-9147,1530-8561

DOI: 10.1093/clinchem/46.4.560a