Preliminary dosimetry investigation of Tc-99m diagnostic radionuclide by NIPAM gel dosimeter

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influencing Factors on Reproducibility and Stability of MRI NIPAM Polymer Gel Dosimeter.

INTRODUCTION At present, the polymer gel dosimeter is considered to be the best possible dosimeter for measuring 3-dimesional radiation dose distribution in radiotherapy. These gels are normally toxic; therefore, manufacturing, handling and discarding them require special attention. In order to find less toxic recipe, N-isopropyle acrylamide polymer gel (NIPAM) was introduced. In this study, th...

متن کامل

Comparison of Tc-99m Ethylenedicysteine (Tc-99m EC) with Tc-99m DPTA in evaluation of renal disease [Persian]

Tc-99m-EC is a new renal radiopharmaceutical introduced as an alternative for Tc-99m MAG3. Twenty-three normal volunteers and patients in different .stages of renal disease were evaluated with Te-99m EC and Tc-99m DTPA. The mean initial uptake of EC was significantly higher as compared to DTPA. There was a high correlation between rectangular and hand-drawn ROls for kidney and background,...

متن کامل

Dose integration and dose rate characteristics of a NiPAM polymer gel MRI dosimeter system

The normoxic polymer gel dosimeter based on N-isopropyl acrylamide (NiPAM) is a promising full 3D-dosimeter with high spatial resolution and near tissue equivalency. NiPAM gel samples were irradiated to different doses using a linear accelerator. The absorbed dose was evaluated using MRI and statistical significance of the analysed data was calculated. The analysis was carried out using an in-h...

متن کامل

A Novel Thin NIPAM Gel Cassette Dosimeter for Photon-Beam Radiotherapy

The response of thin polymer gel cassettes (called NIPAM gels) to ionizing radiation was investigated in this study. The NIPAM gels were prepared from gelatin, N-isopropyl acrylamide, tetrakis (hydroxymethyl) phosphoniumchloride, and N,N'-methylene-bis-acrylamide. Gel cassettes were irradiated in a phantom using a linear accelerator, and the polymerization morphology of irradiated NIPAM gel was...

متن کامل

Basic investigation on performance of low-density polymer gel dosimeter

Background:  In this study a series of basic dosimetric properties of a low-density (LD) gel dosimeter are investigated. The dose response is studied regarding to linearity, sensitivity, dose-rate and energy dependence as well as lung tissue equivalence. Materials and Methods: The LD gel was made by mixing the polymer gel with expanded polystyrene spheres. Energy dependence was studied...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Physics: Conference Series

سال: 2013

ISSN: 1742-6596

DOI: 10.1088/1742-6596/444/1/012106