Preimplantation Flow Testing of Ahmed Glaucoma Valve and the Early Postoperative Clinical Outcome.

PURPOSE The Ahmed glaucoma valve (AGV) implant is designed to prevent early postoperative hypotony. There is evidence of variation in hypotony rates in clinical trials which may be due to surgical technique variation, entry site leakage or valve defects from 'over priming'. We describe a simple preimplantation gravity driven test to assess valve function after priming that may reduce hypotony r...

متن کامل

Clinical findings following Ahmed Glaucoma Valve™ implantation in pediatric glaucoma

PURPOSE To describe clinical findings after Ahmed valve drainage implantation in children. DESIGN All records in one practice were reviewed to identify and describe clinical findings in all children who had undergone Ahmed Glaucoma Valve S2 model insertion for uncontrolled primary or secondary glaucoma. RESULTS A total of 6 patients were identified, ranging in age from 2-15 years. Mean foll...

متن کامل

The Ahmed glaucoma valve in neovascular glaucoma (An AOS Thesis).

PURPOSE To evaluate the results of Ahmed glaucoma valve surgery in neovascular glaucoma and control patients. METHODS In this retrospective comparative study, we reviewed 76 eyes of 76 patients, comparing the surgical outcomes in control patients (N=38) to matched neovascular glaucoma patients (N=38). Success was defined as intraocular pressure (IOP) > or =6 mm Hg and < or =21 mm Hg, without ...

متن کامل

Long-term success of ahmed glaucoma valve in refractory glaucoma.

AIM To evaluate the long-term results and complications of ahmed glaucoma valve (AGV) implantation in refractory glaucoma. METHODS A retrospective review of 13 patients (13 eyes) with refractory glaucoma who underwent AGV implantation and had a minimum follow-up of 18 months was performed. All patients underwent a complete ophthalmologic examination and intraocular pressure (IOP) measurement ...

متن کامل

Clinical efficacy analysis of Ahmed glaucoma valve implantation in neovascular glaucoma and influencing factors

This study aimed to evaluate the efficacy of Ahmed glaucoma valve (AGV) implantation in treating neovascular glaucoma (NVG) and to analyze the factors influencing the surgical success rate.This is a retrospective review of 40 eyes of 40 NVG patients who underwent AGV implantation at Xiangya Hospital of Central South University, China, between January 2014 and December 2016. Pre- and postoperati...