Predietion for Pressure Drop across the Ceramic Tube Filter (CTF).
نویسندگان
چکیده
منابع مشابه
Pressure Characteristics of Multiple-Tube Ceramic Filter Pulse Cleaning System
The dynamic pressure characteristics of pulse jet pipe, pulse jet nozzles and ceramic filter can be measured by high-frequency dynamic pressure sensor. The research is focused on the influence of cleaning pressure, the diameter of nozzles, and the ratio of sectional area of nozzles to that of pulse jet pipe on pulse cleaning performance. The results show that the difference of pulse jet nozzles...
متن کاملA Novel Structure for Optical Channel Drop Filter using Two-Dimensional Photonic Crystals with Square Lattice
In the present paper a novel structure for optical channel drop filter (CDF) based on photonic crystal ring resonator with circular core has been proposed. In order to design the proposed CDF, the plan wave expansion (PWE) method is applied for calculation of band structure and photonic band gap while the transmission characteristics of proposed CDF have been calculated using the finite differe...
متن کاملA New Design for Photonic Crystal Ring Resonator Based Add-Drop Filter Using Nested Rectangular Rings
In this paper using nested Rectangular resonator we have designed an add-drop filter based on photonic crystal structures suitable for optical communication applications. The drop efficiency and the quality factor of our proposed filter is 100% and 2508. In this filter the quality factor is significantly improved with respect to other published reports. The simulation results are obtained using...
متن کاملNovel Design for Photonic Crystal Ring Resonators Based Optical Channel Drop Filter
Photonic crystal ring resonators (PCRRs) are traditional structures fordesigning optical channel drop filters. In this paper, Photonic crystal channel drop filter(CDFs) with a new configuration of ring resonator is presented. The structure is made ofa square lattice of silicon rods with the refractive index nsi=3. 4 which are perforated inair with refractive index nair=1. Calculations of band s...
متن کاملDetermination of the Pressure Drop Across an Arterial Stenosis Utilizing Angiocinedensitometry *
A method is presented for an evaluation of the hemodynamic significance of a stenotic lesion in the arterial tree.Twenty-three patients were examined with arteriosclerosis obliterans and intermittent claudication of the same severity. Flow velocity data obtained by angiodensitometry and viscosity values calculated from the hematocrit were inserted into the Poiseuille's flow formula to obtain th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the Japan Institute of Energy
سال: 2000
ISSN: 1882-6121,0916-8753
DOI: 10.3775/jie.79.840