Prediction of outlet water temperature from cooling towers
نویسندگان
چکیده
منابع مشابه
MINLP Optimization of Cooling Towers
This paper presents a mixed-integer nonlinear programming (MINLP) model for the optimal design of mechanical counter-flow cooling towers, subjected to standard design constraints. The objective function consists of the minimization of the total annual cost, which includes the capital cost of the cooling tower (that depends on the filling material and the air flowrate) and the operating cost (th...
متن کاملReuse of Refinery Treated Wastewater in Cooling Towers
In this report, experimental investigation of waste water treatment by reverse osmosis to enable its reuse in cooling tower is presented. A polyamide spiral wound RO membrane followed by three filters as RO pretreatment (two activated carbon and one cartridge filter) and samples of Tehran refinery treated waste water have been used. The effect of operating conditions such as pressure differ...
متن کاملPrediction of the air temperature and humidity at the outlet of a cooling coil using neural networks
The main objective of this study is to predict air temperature and humidity at the outlet of a wire-on-tube type heat exchanger using neural networks. For this purpose, initially the heat exchanger was coupled to a refrigeration unit and placed in a wind tunnel. Afterwards, its performance was tested under various experimental conditions. We measured nine input parameters, namely, temperature a...
متن کاملLegionella species isolated from cooling towers in Kuala Lumpur.
Three building complexes in Kuala Lumpur were surveyed for the presence of legionellae in cooling towers. The organisms were grown from 12 out of 46 samples of water collected from 30 towers. L. pneumophila serogroups 1 and 7 were the commonest serogroups isolated. None belonged to the Pontiac subgroup of L. pneumophila serogroup 1.
متن کاملOn thermal performance of seawater cooling towers
Seawater cooling towers have been used since the 1970’s in power generation and other industries, so as to reduce the consumption of freshwater. The salts in seawater are known to create a number of operational problems including salt deposition, packing blockage, corrosion, and certain environmental impacts from salt drift and blowdown return. In addition, the salinity of seawater affects the ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IOP Conference Series: Materials Science and Engineering
سال: 2020
ISSN: 1757-899X
DOI: 10.1088/1757-899x/745/1/012078