Prediction of Functional Improvement of Ischemic Myocardium With 123I-BMIPP SPECT and 99mTc-Tetrofosmin SPECT Imaging-A Study of Patients With Large Acute Myocardial Infarction and Receiving Revascularization Therapy-

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dual radioisotopes simultaneous SPECT of 99mTc-tetrofosmin and 123I-BMIPP using a semiconductor detector.

Objective(s): The energy resolution of a cadmium-zinc-telluride (CZT) solid-state semiconductor detector is about 5%, and is superior to the resolution of the conventional Anger type detector which is 10%. Also, the window width of the high-energy part and of the low-energy part of a photo peak window can be changed separately. In this study, we used a semiconductor detector and examined the ef...

متن کامل

Dual radioisotopes simultaneous SPECT of 99mTc-tetrofosmin and 123I-BMIPP using a semiconductor detector

OBJECTIVES The energy resolution of a cadmium-zinc-telluride (CZT) solid-state semiconductor detector is about 5%, and is superior to the resolution of the conventional Anger type detector which is 10%. Also, the window width of the high-energy part and of the low-energy part of a photo peak window can be changed separately. In this study, we used a semiconductor detector and examined the effec...

متن کامل

Myocardial impairment detected by late gadolinium enhancement in hypertrophic cardiomyopathy: comparison with 99mTc-MIBI/tetrofosmin and 123I-BMIPP SPECT.

PURPOSE Myocardial fibrosis is considered to be an important factor in myocardial dysfunction and sudden cardiac death in hypertrophic cardiomyopathy (HCM). The purpose of this study was to compare myocardial fibrosis detected by late gadolinium enhancement (LGE) on cardiac MRI with myocardial perfusion and fatty acid metabolism assessed by single photon emission computed tomography in HCM. M...

متن کامل

dual radioisotopes simultaneous spect of 99mtc-tetrofosmin and 123i-bmipp using a semiconductor detector.

objective(s): the energy resolution of a cadmium-zinc-telluride (czt) solid-state semiconductor detector is about 5%, and is superior to the resolution of the conventional anger type detector which is 10%. also, the window width of the high-energy part and of the low-energy part of a photo peak window can be changed separately. in this study, we used a semiconductor detector and examined the ef...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Circulation Journal

سال: 2005

ISSN: 1346-9843,1347-4820

DOI: 10.1253/circj.69.311