PREDICTION OF FRACTURE MODE OF HAUNCHED AND NON-UNIFORM SECTION BEAM TO RECTANGULAR HOLLOW SECTION COLUMN CONNECTIONS

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Seismic behavior of drilled beam section in moment connections

Abstract: Reduced Beam Section (RBS) and Drilled Beam Section (DBS) are seismic moment resistant frame connections, introduced after 1994 Northridge earthquake. RBS connection has been tested under cyclic loading and showed acceptable performance. In this paper, seismic behavior of Drilled Beam Section (DBS) connection is studied numerically using finite element method. A drilled beam section ...

متن کامل

The Behavior of Type of RC Column-to-Steel Beam Connections and Scrutiny Of Behavior Coefficients

(RCS) frames which are systems that dwell of concrete columns and steel beams , by optimizing the act of compressive strength of concrete and bending strength of steel due to not only a decrease in building weight in comparison to concrete structures but also having a better action in long spans frames . In this paper for analysis RCS behavior, a category of nonlinear Push Over analyses were ...

متن کامل

The Behavior of Type of RC Column-to-Steel Beam Connections and Scrutiny Of Behavior Coefficients

(RCS) frames which are systems that dwell of concrete columns and steel beams , by optimizing the act of compressive strength of concrete and bending strength of steel due to not only a decrease in building weight in comparison to concrete structures but also having a better action in long spans frames . In this paper for analysis RCS behavior, a category of nonlinear Push Over analyses were ...

متن کامل

Pushover Analysis of Steel Seismic Resistant Frames with Reduced Web Section and Reduced Beam Section Connections

The widespread brittle failure of welded beam-to-column connections caused by the 1994 Northridge and 1995 Kobe earthquakes highlighted the need for retrofitting measures effective in reducing the strength demand imposed on connections under cyclic loading. Researchers presented the reduced beam section (RBS) as a viable option to create a weak zone away from the connection, aiding the preventi...

متن کامل

non-linear seismic behavior of concrete beam - column connections

a parametrik investigation was conducted to study the non-linear behavior of precast and cast-in-place reinforced concrete beam-column connections subjected to tabas seismic forces (1979). the behavior of these types of connections in a four stories structure with respect to strength, ductility , stiffness, and bond deterioration at the joint core are presented and discussed. calculation result...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Structural and Construction Engineering (Transactions of AIJ)

سال: 2002

ISSN: 1340-4202,1881-8153

DOI: 10.3130/aijs.67.129_5