Prediction error and accuracy of intraocular lens power calculation in pediatric patient comparing SRK II and Pediatric IOL Calculator

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prediction error and accuracy of intraocular lens power calculation in pediatric patient comparing SRK II and Pediatric IOL Calculator

BACKGROUND Despite growing number of intraocular lens power calculation formulas, there is no evidence that these formulas have good predictive accuracy in pediatric, whose eyes are still undergoing rapid growth and refractive changes. This study is intended to compare the prediction error and the accuracy of predictability of intraocular lens power calculation in pediatric patients at 3 month ...

متن کامل

SRK II formula in the calculation of intraocular lens power.

We studied 400 eyes which underwent cataract extraction with posterior chamber intraocular lens (IOL) implantation to compare the predictive accuracy of various IOL power calculation formulae. The new Sanders-Retzlaff-Kraff (SRK) II formula was more accurate than the original SRK and Binkhorst II formulae. Modification of the A constants used in the SRK II formula to make it 'surgeon specific' ...

متن کامل

Accuracy of intraocular lens power calculation in paediatric cataract surgery.

AIMS To determine the accuracy of intraocular lens (IOL) power calculation in a group of pseudophakic children. METHODS A retrospective analysis of biometric and refractive data was performed on 52 eyes of 40 infants and children, who successfully underwent cataract extraction and IOL implantation. The following parameters were included: age at the time of surgery, keratometry, axial length, ...

متن کامل

Comparison of intraocular lens power calculation using the Binkhorst and SRK formulae: a clinical study.

Comparison of results of intraocular lens implants with IOL powers obtained by Binkhorst and SRK Linear Regression formulae was done using various models and brands of intraocular lenses. Of 887 pseudophakic patients. 415 patients received IOL's with their powers calculated for planned emmetropia, by means of theoretic formula devised by R.D. Binkhorst and in the remaining 472 eyes the IOL powe...

متن کامل

Sources of error in intraocular lens power calculation.

PURPOSE To identify and quantify sources of error in the refractive outcome of cataract surgery. SETTING AMO Groningen BV, Groningen, The Netherlands. METHODS Means and standard deviations (SDs) of parameters that influence refractive outcomes were taken or derived from the published literature to the extent available. To evaluate their influence on refraction, thick-lens ray tracing that a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: BMC Ophthalmology

سال: 2010

ISSN: 1471-2415

DOI: 10.1186/1471-2415-10-20