Aim: To determine any differences between the predictive abilities of the IOL calculation formulas of SRK-II and SRK-T and to compare these using two different IOL types. Methods: A prospective, consecutive, single surgeon clinical trial was conducted on 400 consecutive patients who received routine, standardised phacoemulsification cataract surgery. 200 had cataract surgery and had the Alcon M...
متن کاملPredicting the refractive outcome after cataract surgery: the comparison of different IOLs and SRK-II v SRK-T.
AIM To determine any differences between the predictive abilities of the IOL calculation formulas of SRK-II and SRK-T and to compare these using two different IOL types. METHODS A prospective, consecutive, single surgeon clinical trial was conducted on 400 consecutive patients who received routine, standardised phacoemulsification cataract surgery. 200 had cataract surgery and had the Alcon M...
متن کاملPredicting the refractive outcome and accuracy of IOL power calculation after phacoemulsification using the SRK/T formula with ultrasound biometry in medium axial lengths
PURPOSE To evaluate the accuracy of the SRK/T formula using ultrasound (US) biometry in predicting a target postoperative refraction of ±1.00D in eyes with medium axial length (AL) that underwent phacoemulsification. METHODS The present study was a retrospective analysis, which included 538 eyes with an AL from 22.0 to 24.60 mm that underwent phacoemulsification and foldable intraocular lens ...
متن کاملOptimization of the A Constant for the SRK/T Formula
Purpose: To evaluate the effect of axial length (AL) and the average preoperative keratometry (K) on the A constant in the SRK/T formula. Methods: The retrospective, comparative case series includes 635 eyes from 407 cataract patients from Columbia University Medical Center from January 2006 to August 2010, operated by a single surgeon using a temporal incision and the Acrysof SN60WF IOL (Alcon...
متن کاملIOLMaster biometry: refractive results of 100 consecutive cases.
AIMS To study the refractive outcome of cataract surgery employing IOLMaster biometry data and to compare it with that of applanation ultrasonography in a prospective study of 100 eyes that underwent phacoemulsification with intraocular lens implantation. METHODS The Holladay formula using IOLMaster data was employed for the prediction of implanted intraocular lenses (IOLs). One month after c...