Predicting negligence in female sterilization failure using time interval to sterilization failure: analysis of 131 cases
نویسندگان
چکیده
منابع مشابه
Predicting negligence in female sterilization failure using time interval to sterilization failure: analysis of 131 cases.
BACKGROUND Sterilization failure due to 'tubal non-occlusion' or 'wrong structure sterilization' is considered negligent, whereas 'spontaneous tubal recanalization' or 'fistula formation' is considered non-negligent. We examined whether interval to pregnancy failure was predictive of a negligent rather non-negligent failure mechanism. We aim to test this hypothesis in a selected population seri...
متن کاملFemale Sterilization in Northern Nigeria
Dear Editor, Female sterilization is the most widely used method of family planning.1,2 However, the reluctance to accept family limitation as normal and the deep seated aversion to surgery has affected its practice on a large scale in Nigeria.3 Ignorance and superstition based on religious and ancient principles are contributory.4We undertook a descriptive analysis of 102 female participants w...
متن کاملReversibility of female sterilization.
The discussion considers the current status of reversibility of sterilization in the US and describes clinical and experimental efforts for developing techniques designed for reversibility. It focuses on regret following sterilization, reversal potential of current sterilization techniques, patient selection, current reversal techniques, results of sterilization procedures, experimental approa...
متن کاملMale and female sterilization
Male and female sterilization is used in many countries worldwide as a permanent method of contraception. Failure rates for female sterilization are affected by age at sterilization and by the method of tubal occlusion. Laparoscopic sterilization has low complication rates but is not available in parts of the developing world due to the lack of facilities, equipment and expertise. Less invasive...
متن کاملNonsurgical female sterilization.
The development of a safe, effective nonsurgical method of female sterilization that can be performed by paramedical personnel remains a high priority. The method should have a blind delivery system and require only one application. Methyl cyanoacrylate and quinacrine hydrochloride are the two most promising chemical agents. Quinacrine has evolved from instillations of a solution to the develop...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Human Reproduction
سال: 2007
ISSN: 0268-1161,1460-2350
DOI: 10.1093/humrep/dem188