Predicting implantable collamer lens sizing

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Buffering zone of implantable Collamer lens sizing in V4c

BACKGROUND The purpose of this study was to identify factors related to the unexpected vault in V4c implantable collamer lens (ICL; STAAR Surgical) implantation. METHODS V4c ICLs were implanted in 43 eyes of 43 patients for the correction of myopia. The implanted V4c ICL sizes were determined individually with our previous V4 ICL sizing nomogram based on the sulcus-to-sulcus diameter (STS), a...

متن کامل

Author’s response to reviews Title: Buffering Zone of Implantable Collamer Lens Sizing in V4c Authors:

Title: Buffering Zone of Implantable Collamer Lens Sizing in V4c Authors: Seung Wan Nam ([email protected]) Dong Hui Lim ([email protected]) Joo Hyun ([email protected]) Eui-Sang Chung ([email protected]) Tae-Young Chung ([email protected]) Version: 1 Date: 04 Sep 2017 Author’s response to reviews: Alja Crnej (Reviewer 1): 1. Page 8, line 130 how did you decide what was too large what w...

متن کامل

Measurement of the crystalline lens radius with artemis very high frequency ultrasound biomicroscopy for implantable collamer lens sizing.

To the Editor: In their recent article, Reinstein et al.1 described the use of the Artemis 2 very high frequency digital ultrasound (ArcScan, Inc., Morrison, CO) to calculate the fit of the Visian Implantable Collamer Lens (ICL). Another parameter previously proposed as influencing ICL vaulting is the crystalline lens anterior radius of curvature (ALR).2 The ALR has not yet been used in any pre...

متن کامل

Spontaneous Rotation of a Toric Implantable Collamer Lens

We present a case of toric implantable collamer lens (TICL) spontaneous rotation in a patient with myopic astigmatism. A 23-year-old female underwent TICL implantation. Preoperative uncorrected visual acuity (UCVA) was 20/800 and 20/1200, respectively, with -7.75 -4.25 × 0° and -8.25 -5.25 × 180°. The left eye achieved an UCVA of 20/30. After 3 months of successful implantation of TICL in the l...

متن کامل

Implantable Collamer Lens - Morphological changes induced in the anterior segment

RESULTS: The mean vault values after the first month were 349.93 μm. They remained stable during the first 24 months of the follow-up period, with a slight tendency to decrease at 36 months which was not statistically significant. We observed a reduction in the anterior chamber angle, depth and volume of 14.23°, 167 μm and 60.44 mm3, respectively. This reduction remained stable during the follo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Cataract and Refractive Surgery

سال: 2020

ISSN: 0886-3350,1873-4502

DOI: 10.1097/j.jcrs.0000000000000433