Predicting Central Venous Pressure by Measuring Femoral Venous Diameter Using Ultrasonography

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Predicting Central Venous Pressure by Measuring Femoral Venous Diameter Using Ultrasonography

OBJECTIVES The objective of this exploratory study was to find out the correlation of femoral vein diameter (FVD) to central venous pressure (CVP) measurements and to derive a prediction equation to help ascertain the fluid volume status in a critical patient. PATIENTS AND METHODS This was a single-centered prospective cohort study designed and conducted by the critical care department of Shi...

متن کامل

The relationship between inferior vena cava diameter measured by bedside ultrasonography and central venous pressure value

OBJECTIVE We aimed to present inferior vena cava (IVC) diameter as a guiding method for detection of relationship between IVC diameter measured noninvasively with the help of ultrasonography (USG) and central venous pressure (CVP) and evaluation of patient's intravascular volume status. METHODS Patients over the age of 18, to whom a central venous catheter was inserted to their subclavian vei...

متن کامل

Determination of Central Venous Pressure from Intraocular Pressure

Background: In many clinical situations, knowledge of central venous pressure (CVP) is important.  Measurement of CVP is not always possible. Objective: To determine if intraocular pressure (IOP) can be used as an estimate for CVP. Methods: IOP and CVP were measured concurrently in 30 candidates of coronary artery bypass graft surgery.  Those with carotid artery or jugular venous diseases as we...

متن کامل

measurement of anterior–posterior diameter of ivc by ultrasonography: a non invasive method for estimation of central venous pressure.

introduction:the assessment of intravascular volume in severely traumatized patients or patients admitted in icu is very essential. at present the accurate method for estimating the intravascular volume requirement is by measuring the cvp which is an invasive method. the measurement of ivc diameter by ultrasound has been suggested as an easily available and simple method for measuring the intra...

متن کامل

Defining normal jugular venous pressure with ultrasonography.

OBJECTIVE Determination of jugular venous pressure (JVP) by physical examination (E-JVP) is unreliable. Measurement of JVP with ultrasonography (U-JVP) is easy to perform, but the normal range is unknown. The objective of this study was to determine the normal range for U-JVP. METHODS We conducted a prospective anatomic study on a convenience sample of emergency department (ED) patients over ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Cureus

سال: 2016

ISSN: 2168-8184

DOI: 10.7759/cureus.893