Pre-Compressed Foam Sealing Tapes to Seal Joints between Building Envelope Components Watertight: An Experimental Assessment

نویسندگان

چکیده

Currently there is gaining interest in pre-compressed foam sealing tapes to seal joints watertight between different building envelope components. Little no information available on the parameters affecting resistance of these driving rain. On other hand, several research studies have shown that water leakages can be expected at relatively low-pressure differences and drainage should provided. Therefore, a study was designed one hand assess material installation affect watertightness polyurethane impregnated with an acrylic polymer dispersion evaluate potential providing possibilities, either as two-barrier system or by means integrated cavities. It found joint width, presence airtight coating, position tape relative exterior surface affected sealed joints. Notably, 87% evaluated applied single barrier showed pressure 600 Pa lower. Foam cavities, resulted up average difference 825 Pa.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sealing Faceted Surfaces to Achieve Watertight CAD Models

Solid modeling engines are capable of faceting CAD models but may facet each face independent of adjacent faces. Regions of the resulting model have gaps between faces of their boundaries. An algorithm is described to seal faceted CAD models such that the boundary of neighboring faces has the same discretization along their shared edges. The algorithm works by sealing skin edges of geometric fa...

متن کامل

Zero Energy Building Envelope Components: A Review

With some recent developments, the zero energy building and near zero energy building has gained a worldwide attention and now it is seen as the future building concept. Since such buildings are now the center of attraction, various advancements in this area are being reported. This paper is a detailed review of the literature on the zero (or near zero) energy building (ZEB) envelope components...

متن کامل

Dynamic Envelope and Control Shading Pattern to Visual Comfort of Office Building in Tehran

This work reviews the effect of parametric programming on visual performance, daylighting and shading in office buildings in Tehran-Iran and studies their influences that help not only to reduce the glare but also to promote useful daylight illuminance through promoting visual comfort. It starts by establishing a review of the effective parameters on visual comfort indices, glare indices, and d...

متن کامل

Infrared Thermography Assessment of Thermal Bridges in Building Envelope: Experimental Validation in a Test Room Setup

Thermal infrared imaging is a valuable tool to perform non-destructive qualitative tests and to investigate buildings envelope thermal-energy behavior. The assessment of envelope thermal insulation, ventilation, air leakages, and HVAC performance can be implemented through the analysis of each thermogram corresponding to an object surface temperature. Thermography also allows the identification...

متن کامل

Sealing Performance of a Mobile AC Compressor Shaft Seal

In the last years, environmental concerns such as the destruction of the ozone layer and global warming led to the demand of tighter air conditioning (AC) systems. The compressor has been identified as the most emissive component of the AC system. Due to its complex structure and sealing mechanism, the shaft seal is the leak-prone part. This paper presents an experimental study of several lip s...